bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.09.12.675841

Stable isotope tracer captures the anabolic response of human skeletal muscle microtissues undetected by puromycin labeling

Abstract

Skeletal muscle microtissues are valuable in vitro models for studying the stimuli regulating muscle protein synthesis (MPS), the key determinant of changes in muscle mass. Differentiated between opposing posts, microtissues contain aligned, contractile myotubes, providing a controlled system for investigating the responses of skeletal muscle to nutrient and contractile stimulation. However, microtissue MPS responses to these stimuli remain under-characterized. Stable isotope-labeled amino acid tracers deliver sarcoplasmic and myofibrillar fractional synthetic rates (FSR) for MPS in human studies, but have not been implemented in engineered skeletal muscle. We close these gaps by characterizing stimulation-induced MPS, in microtissues and 2D myotubes derived from the same primary myoblast line, using stable isotope tracers and puromycin incorporation. In microtissues, sarcoplasmic FSR increased significantly during the two-hour period following amino acid treatment (p < 0.0001), whereas myofibrillar FSR remained unchanged (p = 0.159). However, both fractions were unresponsive to ketone stimulation and contraction (all p [&ge;] 0.703). 2D myotubes showed significant increases in sarcoplasmic and myofibrillar FSR in response to amino acid treatment (both p = 0.002). Notably, microtissues demonstrated a more stable myofibrillar protein fraction, with a sarcoplasmic-to-myofibrillar FSR ratio of [~]2:1 which closely resembled that of native human muscle. The puromycin-based approach failed to detect MPS responses to any stimulus (all p [&ge;] 0.677), highlighting the superior sensitivity of tracer-based measurements, particularly where longer timescales are needed to capture an effect. These findings support the use of engineered muscle and isotope-derived measurements of MPS in future studies of stimuli regulating skeletal muscle mass. New FindingsO_ST_ABSWhat is the central question of this study?C_ST_ABSStable isotope tracers are emerging as a powerful approach to measure fraction-specific protein synthesis. However, their efficacy relative to conventional puromycin labeling remains unreported, and they have not been applied to engineered skeletal muscle. What is the main finding and its importance?By implementing stable isotope tracers in engineered muscle, we showcase the ability to capture anabolic responses that are undetected by puromycin-based methods. We found that the myofibrillar protein fraction of microtissues is more stable than the sarcoplasmic fraction, a property of native muscle, absent in 2D myotubes. These findings demonstrate the physiological relevance of engineered muscle and support the adoption of isotope-derived measurements in future studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tiper, Y., Tinline-Goodfellow, C. T., Moore, D. R., Gilbert, P. M.. 2025-09-17. Stable isotope tracer captures the anabolic response of human skeletal muscle microtissues undetected by puromycin labeling. https://doi.org/10.1101/2025.09.12.675841

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗