bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.08.27.671384

Human progenitor T-cell differentiation regulated by the mechanical resistance of thymus-mimetic extracellular matrices

Abstract

Therapeutic T-cell engineering ex vivo from human hematopoietic stem cells (HSCs) focuses on recapitulating notch1-signaling and 4{beta}1-integrin-mediated adhesion within the thymic niche with supportive stromal cell feeder-layers or surface-immobilized recombinant protein-based engineered thymic niches (ETNs). The relevant Notch1-DLL-4 and 4{beta}1-integrin-VCAM-1 interactions are known to respond to mechanical forces that regulate their bond dissociation behaviors and downstream signal transduction, yet manipulating the mechanosensitive features of these key receptor-ligand interactions in thymopoiesis has been largely ignored in current ETN designs. Here, we demonstrate that human T-cell development from cord blood-derived CD34+ HSCs is regulated via molecular cooperativity in notch1 and integrin-mediated mechanotransduction. Mechanically confining interpenetrating network (IPN) hydrogel-based 3D cell culture comprised of collagen type I and alginate polysaccharides functionalized with DLL-4 and VCAM-1 is used as a model viscoelastic 3D ETN to manipulate human progenitor (pro)T-cell differentiation. This ETN enables orthogonal control of the mechanical and biomolecular features of the thymic niche, including thymopoietic ligand density, modulus, and viscoelastic properties (e.g., stress relaxation kinetics). We identify that soft, viscous matrices that enhance activation of the notch1-pathway, and subsequently notch1 intracellular domain (NICD) nuclear import sustain the T-cell development gene regulatory network during proT-cell differentiation. Conversely, stiff, elastic matrices inhibit HSC commitment to the T-lineage, and rather promotes Myeloid-cell differentiation. Our observations indicate mechanical reciprocity in signaling pathways indispensable to thymopoiesis, and highlights extracellular matrix mechanics as a variable in controlling hematopoietic stem cell fate decisions.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeffreys, N., Ruark, K. T., Price, J., Serrano-Wu, E. M., Hanan, B., Khalil, A. S., Jung, W.-H., Lafuente-Gomez, N., Brockman, J. M., Lu, A., Zmirska, I., Vining, K. H., Lou, J., Adu-Berchie, K., Kwon, S., Ijaz, H., Sharda, A., Scadden, D. T., Mooney, D. J.. 2025-08-27. Human progenitor T-cell differentiation regulated by the mechanical resistance of thymus-mimetic extracellular matrices. https://doi.org/10.1101/2025.08.27.671384

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗