bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.08.26.672476

Orthogonal and Robust Analytics Enable Reproducible and Scalable Manufacturing of High Purity Extracellular Vesicles Derived from Mesenchymal Stromal Cells

Abstract

The development of extracellular vesicle (EV) based therapeutics requires robust analytical assays and scalable downstream processing (DSP) strategies to ensure product quality and reproducibility. In this study, we established an analytical toolbox comprising scattering and fluorescence mode nanoparticle tracking analysis (NTA), fluorescence-based flow cytometry (Fl-FC), and multi-detector analytical size exclusion chromatography. Liposomes, selected for their physicochemical similarity to EVs, were used as reference materials to optimize assay parameters, fluorescence labeling conditions, and dynamic range, minimizing artifacts such as photobleaching and masking effects. Using these optimized analytical tools, we designed a scalable DSP workflow for human bone marrow mesenchymal stromal cell (hBM-MSC) derived EVs, incorporating clarification, tangential flow filtration (TFF), ion exchange chromatography (IEX), buffer exchange, and sterile filtration. IEX chromatography resulted in the elution of two cell-secreted populations, with similar scattering signals while eluate 1 showed approximately 30 times higher absorbance signal compared to eluate 2. Transmission electron microscopy revealed that eluate 1 contained non-vesicular extracellular particles (NVEPs), and eluate 2 was enriched in EVs and showed higher expression of positive markers such as CD81 and CD73 using Simple Western. Additionally, the two IEX eluates showed different proteomic and lipidomic profiles. Then the analytical toolbox was utilized to monitor the DSP process in terms of particle recovery and impurity removal throughout the process determining the high purity level of the final EV preparation. Together, these results demonstrate that orthogonal analytics coupled to a scalable DSP yield reproducible MSC-EV preparations while depleting commonly co-isolated NVEPs. This practical framework advances process analytics of MSC-EV manufacturing and supports reporting of identity, purity, and function aligned with existing guidelines in the field. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=91 SRC="FIGDIR/small/672476v1_ufig1.gif" ALT="Figure 1"> View larger version (26K): org.highwire.dtl.DTLVardef@142ff8aorg.highwire.dtl.DTLVardef@196c0bforg.highwire.dtl.DTLVardef@485c36org.highwire.dtl.DTLVardef@9dff39_HPS_FORMAT_FIGEXP M_FIG C_FIG Liposomes were used as reference materials to optimize single particle analytics as well as multi detector analytical chromatography to assess particle recovery and impurity removal. This optimized analytical toolbox enabled accurate monitoring of downstream processing steps, establishing a robust workflow for reproducible and scalable mesenchymal stromal derived extracellular vesicles bioprocessing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dehghani, M., Chai, M., Talebloo, N., Morrissey, M., Larey, A., Kim, Y., Trinidad, C., Joshi, D., Wu, Y., Zhong, Y., Cheng, R., Lu, Y., Lahooti, B., Islam, M., Zhao, Z., Speidel, J., Keselman, P., Mukherjee, P., Mayo, M., Black, E., Splan, D., Haridas, N., Marks, P., Chon, J., Kishimori, E., Gaborski, T.. 2025-08-31. Orthogonal and Robust Analytics Enable Reproducible and Scalable Manufacturing of High Purity Extracellular Vesicles Derived from Mesenchymal Stromal Cells. https://doi.org/10.1101/2025.08.26.672476

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗