bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.07.09.663931

Matrix compliance regulates cellular and nuclear confinement of fibroblasts in tunable protein-based hydrogel microenvironments

Abstract

The extracellular matrix (ECM) influences cellular behavior, fate, and various mechanisms underlying homeostasis, development, and disease. Biophysical and biochemical properties of the ECM are known to affect three-dimensional (3D) cellular behavior, and phenotype that regulate a wide range of pathological conditions. Tunable biomimetic hydrogels are extensively employed to regulate cellular dynamics in defined 3D microenvironments, enabling detailed investigation of cell-matrix interactions. This study aims to establish the relationship between varying hydrogel properties (adhesivity, degradability, porosity, and stiffness, hereby collectively referred to as matrix compliance) and fibroblast morphology at the cellular and nuclear levels. Poly(ethylene glycol diacrylate)-fibrinogen (PF)-based hydrogels were fabricated and their matrix properties were tuned using two different non-degradable co-monomers of varying molecular weights and concentrations. NIH3T3 mouse fibroblasts were cultured in 3D hydrogels for 10 days and their cellular and nuclear morphology was analyzed via confocal imaging. Cells in degradable, soft, porous, and adhesive hydrogels displayed higher degree of spreading, higher cell density, longer protrusions, and elongated and larger nuclei compared to those in less degradable, stiffer, less porous, and less adhesive hydrogels. Matrix compliance conjointly regulated cell density, protrusion length, and protrusion frequency (collectively referred to as cellular confinement) and nuclear volume (referred to as nuclear confinement). These results highlight the complex interplay and interdependence of these cellular and nuclear morphological features as regulated by engineered tunable matrices, providing guidance for future studies of 3D cell behavior in novel biomaterials. Statement of significanceBiomimetic tunable hydrogels are commonly used to support, and control, three-dimensional (3D) cellular behavior to recapitulate various developmental processes and disease states. Specific biophysical and biochemical characteristics of the extracellular matrix (ECM) can be modeled using these hydrogels by controlling the compositions and crosslinking mechanisms. Using this approach, the behavior of cells in 3D hydrogel matrices can be correlated with the matrix properties, thereby providing mechanistic insights into cell-matrix interactions. This study assesses the variations in the morphological features of fibroblasts encapsulated in 3D protein-based hydrogel matrices with varying crosslinking mechanisms. Our results reveal the combinatorial role of matrix adhesivity, degradability, porosity, and stiffness in regulating cellular and nuclear confinement of fibroblasts in 3D microenvironments. Overall, this study elucidates how matrix characteristics influence cellular behavior, serving as a practical guide for researchers developing innovative biomaterial matrices for 3D cell culture applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Patra, I. P., Sabarinath, S., Sarkar, S., Deshpande, A. P., Pradhan, S.. 2025-07-14. Matrix compliance regulates cellular and nuclear confinement of fibroblasts in tunable protein-based hydrogel microenvironments. https://doi.org/10.1101/2025.07.09.663931

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗