bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.06.22.659147

Integration of customizable 3D printed mixing printheads for controlled and tuneable material and stiffness gradient fabrication with high cell viability in extrusion-based bioprinting

Abstract

The fabrication of native tissue-like structures with gradual transitions in material properties, cell types and growth factors remains a major challenge in biofabrication. Particularly the complex hierarchical organization, present in living tissues, has to be mimicked as close as possible for the created models to fulfil the desired function. However, the fabrication of gradual structures incorporating several materials ensuring high cell survival and subsequent unaffected tissue maturation is highly challenging. To get a step closer to the goal of generating tissue models containing controlled gradient structures, here we show a novel approach combining extrusion- based 3D bioprinting with static mixing, using self-designed Digital Light Processing (DLP) printed mixing units to fabricate defined gradual structures. Two passive mixing geometries, sinusoidal and obstacle-based, are designed and fabricated and benchmarked against commercially available static mixers. The mixing performance is assessed pixelwise using dyed alginate solutions that are extruded through the mixers using an adapted 3D printer equipped with cavity pumps. The obstacle structure exhibits the highest mixing rate compared to the sinusoidal design and commercially available static mixers. Beyond mixing efficiency, the biological compatibility of the systems is assessed by evaluating the viability of U87 and NIH3T3 cells after extrusion. Two distinct polymer solutions of differing viscosities, composed of allyl-modified gelatin (gelAGE), polyethylene glycol dithiol (PEG-2-SH), and Matrigel, are extruded through the static mixer, revealing significantly higher cell viability in the self-designed printheads compared to commercial mixers. Subsequently, graded structures mimicking the mechanical profile of native brain tissue are fabricated and mechanically characterized using nanoindentation, confirming the successful generation of continuous stiffness gradients. In summary, this study demonstrates that combining extrusion-based 3D printing with customizable mixing units enables the controlled fabrication of tissue-like gradient structures with enhanced mixing rates and cell viability. The design flexibility and rapid fabrication of DLP-printed printheads enable the adaptation to specific tissue requirements, providing a robust platform for future developments in biofabrication and tissue engineering. This work serves as foundation for the creation of increasingly complex and functional tissue models.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hofmann, F., Faber, J., Moser, F., Cianciosi, A., Murenu, N., Schenk, J., Heinze, K., Schaefer, N., Budday, S., Jungst, T.. 2025-06-26. Integration of customizable 3D printed mixing printheads for controlled and tuneable material and stiffness gradient fabrication with high cell viability in extrusion-based bioprinting. https://doi.org/10.1101/2025.06.22.659147

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗