bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.05.31.657128

Oxidative stress mediates cardiac electrophysiological injury in inhalation exposure to flavored vaping products.

Abstract

BackgroundElectronic nicotine delivery systems (ENDS) heat "E-liquids" to generate "E-vapor", an aerosolized mixture containing nicotine and flavors. Flavored ENDS are popular among teens who vape, however, the possible cardiac electrophysiological harm of inhalation exposure to flavored ENDS are not fully understood. ObjectiveTo test if inhalation exposure to flavoring carbonyls in E-liquids compromises mitochondrial integrity, increases oxidative stress, and leads to cardiac electrophysiological toxicity. MethodsGas chromatography mass spectrometry (GC/MS), flow cytometry, oxygen consumption rate (OCR) measurement, in-vivo programmed electrical stimulation (PES), and multielectrode array (MEA) were used in atrial like HL-1 myocytes, hiPSC derived cardiomyocytes, and mice overexpressing mitochondrial catalase (mCAT). ResultsWe compared the toxicity of E-vapor exposure from 30 differently flavored E-liquids in HL-1 cells using apoptotic annexin V flow cytometry. Most E-liquids were toxic. We identified the major flavoring carbonyls in these E-liquids and quantified their concentrations using GC/MS. Linear regression analysis showed that toxicity correlated with carbonyls concentration. Using flow cytometry of CellROX and TMRE staining, HL-1 cells exposed to flavored E-vapor showed increased reactive oxygen species and depolarized mitochondrial membrane potential. Additionally, exposure decreased OCR in these cells. In-vivo inhalation exposure to flavored E-vapor increased the inducible ventricular tachycardia duration in WT but not in mCAT mice compared to controls. MEA recordings in hiPSC derived cardiomyocytes exposed to flavored E-vapor, with or without nicotine, resulted in changes in the spontaneous beating rate. ConclusionsInhalation exposure to flavored ENDS negatively affects ventricular electrophysiology, in part via adverse mitochondrial remodeling, and increased oxidative stress.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Abou-Assali, O. J., Reiser, M., Chang, M., Chidipi, B., Asswaytte, R., Zhang, Y., Szekeres, C., Calcul, L., Noujaim, S. F.. 2025-06-03. Oxidative stress mediates cardiac electrophysiological injury in inhalation exposure to flavored vaping products.. https://doi.org/10.1101/2025.05.31.657128

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Thoracoabdominal pressure transmission during prone and supine cardiopulmonary resuscitation in fresh-frozen human cadavers

Background: Prone cardiopulmonary resuscitation (CPR) may be necessary when turning a prone patient supine would delay chest compressions. Although prone compressions can generate arterial pressures comparable with or greater than supine CPR, the pathway of pressure transmission is uncertain. We examined synchronized intrathoracic, intra-abdominal, and central arterial pressures in both supine and prone positions. Methods: Two thawed fresh-frozen adult cadavers underwent three, 2-minute mechanical CPR trials per position in a counterbalanced crossover sequence. Solid-state catheters recorded pleural, peritoneal, and central arterial pressures simultaneously. Trial-level outcomes included peak pressure, mean pressure, pressure-time area, and the mean peritoneal-to-pleural pressure gradient. Exploratory fixed-effects models included position, cadaver, and their interaction. Results: Prone CPR increased peak intrathoracic pressure by 7.04 mmHg, peak intra-abdominal pressure by 21.69 mmHg, and peak arterial pressure by 15.40 mmHg. Mean intra-abdominal and arterial pressures increased by 16.22 and 9.90 mmHg, respectively. The mean peritoneal-to-pleural gradient reversed direction from -8.46 mmHg supine to 4.85 mmHg prone. Intrathoracic pressure-time area increased 3.4-fold, from 1.62 to 5.46 mmHg{middle dot}s, and arterial pressure-time area increased 2.2-fold, from 2.96 to 6.42 mmHg{middle dot}s. Conclusions: Compared to supine, prone mechanical CPR generated higher arterial pressures and reversed the pressure relationship across the thoracoabdominal boundary in both cadavers. Higher abdominal pressure coincided with a larger intrathoracic pressure-time area, a pattern compatible with reduced caudal pressure dissipation.

physiology↗

Genetic Variation, Iron Status, and FGF23 Signaling Converge to Regulate Renal Calcium Buffering in Sickle Cell Disease

Sickle cell disease (SCD) causes heterogeneous mineral imbalances including variable degrees of hypocalcemia. The kidney controls systemic calcium by reabsorbing calcium from the glomerular filtrate via paracellular transport and transcellular transport in the nephron tubules, yet it is unknown whether these processes are modulated by genetic or environmental factors or disrupted in SCD. Using SCD mouse models and single-cell multiomics, we identify the distal convoluted tubule (DCT) as the nephron segment most susceptible to calcium reabsorption dysfunction in SCD, mainly via reduction of calcium buffer protein calbindin 1 (CALB1). We show that CALB1 and its encoding mRNA are decreased in DCT cells in SCD, alongside decreased Klotho (KL)-dependent fibroblast growth factor (FGF) 23 signaling and intracellular calcium signaling. Dietary iron restriction reduces CALB1, KL, and calcium exporter SLC8A1 levels in SCD kidneys. Loss of CALB1 shifts DCT cells toward energy-inefficient glycolysis with the metabolite 2,3-diphosphoglycerate impairing KL-dependent FGF23 signaling to create a feed-forward loop suppressing calcium reabsorption. Analysis of gene expression and protein quantitative trait loci data from kidneys of genetically diverse mice revealed that Calb1 expression levels are highly heritable and co-regulated with Slc8a1, identifying a genetic axis that dictates differential capacities for calcium buffering and trafficking toward blood in the kidney. Together, these findings support a model in which genetic variation, dietary iron status, and FGF23 signaling converge on DCT calcium buffering to reduce renal calcium reabsorption in the SCD kidney. This points to personalized, genotype- and iron-dependent strategies for managing mineral metabolism in SCD patients.

physiology↗

Silver spoon effect: early-life environment and adult survival in a primate.

Early environmental conditions can have long-lasting effects on survival and reproductive fitness. Using a 23 year-long monitoring data set of captive mouse lemur's life history traits, we tested a relationship between maternal allocation to offspring (N = 1365) and their adulthood survival. Maternal characteristics such as age or body condition did not affect allocation to offspring whatever the litter size (1 to 3). Although birth mass depended on size and composition of the litters, mouse lemur survival was highly correlated with body mass acquired after weaning in both sexes, through potential sibling competition. Moreover, female's reproductive success correlated with this body mass and was consistently associated with increased longevity. These findings suggest the presence of a silver spoon effect under constant captive conditions. However, cumulative effects of genetic and adulthood social conditions strongly interact to affect adult survival. Deaths related to intra- or inter-sexes aggressive social interactions may outweigh effect of early environment and therefore minimize the silver-spoon effect on captive mouse lemur's survival. However, having a high body mass after weaning appeared to be a determinant factor in individual survival for mouse lemurs.

physiology↗