bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.05.26.656075

Computational design of monomeric Fc variants with distinct pH-responsive FcRn-binding profiles

Abstract

IgG1 and IgG4 antibodies form a [~]150 kDa homodimer through dimerization of the Fc domain, which prolongs their in vivo half-life via pH-dependent binding to the neonatal Fc receptor (FcRn). Conformationally stable, half-life-extended monomeric Fc (mFc) variants offer a promising platform for antibodies and Fc-fusion therapeutics, enabling deeper tissue penetration, reduced toxicity, and simplified manufacturing. Due to the loss of binding avidity, mFc requires significantly enhanced FcRn-binding affinity at pH 6.0, but retaining weak binding at neutral pH to achieve comparable serum half-life, making engineering such mFc variants highly challenging. Mainly by computational design approach, we created mFc mutants with diverse human FcRn-binding profiles, including two variants that exhibit 17- and 47-fold stronger FcRn binding at pH 6.0 (KD of 30.7 nM and 88 nM) compared to a baseline mFc, while maintaining greater than 213-fold weaker binding at pH 7.4 (KD of 6,549 nM and 39,150 nM). These variants are highly soluble and display a melting temperature greater than 60.6 {degrees}C, underscoring their potential as platforms for extending the in vivo half-life of therapeutic modalities. Other mFc variants with different pH-responsive FcRn-binding profiles would potentially fit for other therapeutic needs. Moreover, transferring the same variations into IgG4 Fc generated IgG4 mFc variants with FcRn-binding properties similar to those of the parent IgG1 mFc variants. Furthermore, incorporating the FcRn-binding affinity-enhancing substitutions into native Fc produced a dimeric Fc variant that exhibits strong, pH-responsive FcRn-binding affinities, promising an extended half-life in serum.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeon, J.-Y., Lee, H., Choi, S., Suh, S., Im, S.-B., Kim, Y.-G., Ku, B. M., Ahn, M.-J., Jeong, B.-s., Oh, B.-H.. 2025-05-29. Computational design of monomeric Fc variants with distinct pH-responsive FcRn-binding profiles. https://doi.org/10.1101/2025.05.26.656075

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗