bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.05.26.652827

Human Skin Model from 15 GHz to 110 GHz

Abstract

In the recently revised guidelines for electromagnetic safety, basic restrictions expressed in terms of the absorbed power density (APD) at frequencies higher than 6 GHz were introduced. Testing for APD compliance of wireless devices requires experimental and numerical body models or phantoms that conservatively reproduce the absorption characteristics of human skin. Previous studies of APD indicate that frequency-dependent impedance-matching effects are caused by the low-permittivity stratum corneum (SC) layer. The objective of this study is to complement previous work (Christ et al., 2020) and to develop dispersive dielectric models to represent reflection and absorption of electromagnetic fields at the surface of the skin across a frequency range up to 110 GHz. The reflection coefficient of the skin of human volunteers was measured at frequencies of 15 to 43 GHz with open waveguide probes, complementing previous data from 45 to 110 GHz (Christ et al., 2020). The volunteers represented both sexes and different age groups and occupations; measurements were made at various regions of the body. The statistical analysis of the results show that the reflection coefficient follows a normal distribution in regions where the SC is relatively thin, which permits development of a conservative skin model that covers the 95th percentile of the tested population. As expected, in regions where the SC is thicker, e.g., the palms, the reflection coefficient is not normally distributed, because the thickness of the SC depends on the mechanical stress and friction to which the hands are exposed during routine daily activities. There was no evidence of relevant differences due to sex, but there is evidence for a slight age-dependent difference. The measured data - via fitting to the numerical model - allow the derivation of two-layer dielectric dispersive models that represent absorption and reflection at the surface of the skin with known uncertainty. The proposed models can be used to conservatively demonstrate compliance with the APD limits of wireless devices operating at frequencies of up to 110 GHz in any of the 5G and 6G bands defined. HighlightsO_LIbroadband evaluation of the skin reflection coefficient with open waveguide probes; C_LIO_LIcorroboration of increased absorption of millimeter wave radiation in body regions with increased stratum corneum thickness; C_LIO_LIdispersive dielectric models representing reflection and absorption at the skin surface with known population coverage. C_LI

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christ, A., Aeschbacher, A., Tarigan, B., Chitnis, N., Fallahi, A., Kuehn, S., Capstick, M., Kuster, N.. 2025-05-28. Human Skin Model from 15 GHz to 110 GHz. https://doi.org/10.1101/2025.05.26.652827

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗