bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.05.15.654200

Rational Design and Modeling of Auxetic Fiber Scaffolds for Soft Tissue Engineering via Melt Electrowriting

Abstract

BackgroundThe development of regenerative biomaterial scaffolds with mechanical properties tailored to native soft tissues remains a challenge in tissue engineering. Mechanical metamaterials with auxetic architectures have taken enormous flight over the past years, as they offer improved control over mechanical function and performance through spatially defined material architecture. However, despite their potential, auxetic scaffold designs are often developed empirically, and the relationship between scaffold microarchitecture, mechanical function, and manufacturability remains poorly defined, limiting their applicability in tissue engineering. In this study, we present a computational framework for the rational design of auxetic fiber scaffolds manufactured using Melt Electro-writing (MEW) for soft tissue engineering. To address the challenge of tailoring scaffold mechanical properties to native tissue, we integrated finite element method (FEM) modeling with experimental validation to predict the mechanical behavior of the scaffolds. MethodThe micro-fibrous scaffolds with customizable auxetic re-entrant structures were designed using Python scripts for generating G-code used in fabrication and for model definition in FEM modeling, respectively. Four distinct auxetic structures - HCELL, SREG, SINV, and STRI - were selected for this study to cover the wide range of mechanical properties of soft tissue, and their geometry parameters were adjusted to reduce the pore size while considering printing resolution. FEM modeling was employed to predict the mechanical behavior of the scaffolds. To validate the predictions, the scaffolds were manufactured via MEW and characterized mechanically under biaxial tensile loading. Results and conclusionMEW manufacturing enabled the production of auxetic fiber scaffolds with sub-millimeter pore resolution, while rational design allowed to correct fabrication discrepancies and improve printed design fidelity. Experimental biaxial characterization of the scaffolds revealed design-dependent, biphasic, non-linear mechanical response, and the developed FEM model was capable of not only accurately simulating the observed mechanical response but also accounting for variations introduced by MEW during fabrication. Additionally, auxetic scaffolds supported fibroblast viability over 7 days, confirming biocompatibility as a first step toward soft tissue engineering. The good alignment between numerical predictions and experimental results highlights the value of FEM modeling as a powerful computational tool for guiding the design and optimization of auxetic scaffolds with tailored mechanical performance for specific soft tissue requirements. The presented methodology offers a significant advancement in the development of functional biomaterials for biomedical applications.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lecina-Tejero, O., Iamsamang, J., Alaman-Diez, P., Garcia-Gareta, E., Cuartero, J., Perez, M. A., Castilho, M., Borau, C.. 2025-05-20. Rational Design and Modeling of Auxetic Fiber Scaffolds for Soft Tissue Engineering via Melt Electrowriting. https://doi.org/10.1101/2025.05.15.654200

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗