bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.04.21.649819

Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T

Abstract

PurposeTo demonstrate the feasibility and performance of mesoscopic whole brain T2*-weighted (T2*w) MRI at 10.5 T by combining a motion-robust multi-echo gradient-echo (GRE) method with high-density RF receive arrays. MethodsMulti-echo GRE data were collected in healthy adults at isotropic 0.5 mm resolution using a custom-built 16-channel transmit/80-channel receive (16Tx/80Rx) RF coil. Whole brain images were reconstructed with navigator-guided joint motion and field correction and were used for quantitative R2* and susceptibility ({chi}) mapping. Intrinsic signal-to-noise ratio (iSNR) and quantification precision for R2* and{chi} were also estimated. The results were compared with those obtained in the same subjects with matched resolution at 7 T using the commercial Nova 1Tx/32Rx coil, to demonstrate the iSNR and quantification precision gains at 10.5 T. G-factors were also calculated at each field strength to evaluate parallel imaging performances. To demonstrate the benefit of increased parallel imaging performances at 10.5 T, whole brain images with higher acceleration were also obtained using a custom-built 16Tx/128Rx coil. Resultsthe utilized motion robust GRE sequence and reconstruction effectively reduced artifacts from motion and field changes during scans, producing high-quality whole-brain T2*w images and multi-parametric maps at 10.5 T with delineation of fine-scale brain structures. Compared to 7 T, the 10.5 T approach led to gains in both iSNR and quantification precision of R2* and{chi} . Quantitatively, iSNR estimated in the peripheral cortical gray matter increased by 42%. Parallel imaging performances were also improved at 10.5 T owing to the utilized high-density coils compared to the commonly used commercially available coil at 7 T, allowing high-quality images with up to 12-fold combined acceleration when using the 128Rx coil. ConclusionIt is feasible to perform motion-robust whole-brain mesoscopic multi-echo gradient echo imaging of the human brain at 10.5 T. Intrinsic SNR and quantification precision of R2* and{chi} were estimated and compared with 7 T results. The results presented here may shed light on future optimal implementation of anatomic T2*w brain MRI at ultrahigh field beyond 7 T.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Liu, J., Van Gelderen, P., de Zwart, J. A., Duyn, J. H., Huang, Y., Grant, A., Auerbach, E., Waks, M., Lagore, R. L., Delabarre, L., Tarakameh, A. S., Eryaman, Y., Adrian, G., Ugurbil, K., Wu, X.. 2025-04-24. Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T. https://doi.org/10.1101/2025.04.21.649819

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗