bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.04.07.647583

Small Accelerations of the cell generate sufficient nuclear motion to modulate transcriptional activity, driving cellular response independent of matrix strain

Abstract

The cells mechanical environment is a fundamental determinant of its activity. Ostensibly, the cellular response is dependent on interactions between extracellular matrix deformations and the cell adhesome. Low-intensity vibration (LIV) induces sinusoidal mechanical accelerations that stimulate mesenchymal stem cell (MSC) anabolism despite generating minimal matrix strain. In this study, we tested the hypothesis that accelerations of less than 1g cause nuclear motions relative to the cell membrane in adherent cells, resulting in elevated stresses in the cytoskeleton that promote transcriptional activity. Coupling a piezoelectric vibration platform with real-time microscopy, we applied a 0.7g, 90Hz LIV signal that oscillates the cell with displacements of up to {+/-}11 {micro}m. Live-cell tracking revealed that the sinusoidal vibrations caused the nucleus to move {+/-}1.27 {micro}m (17% of total displacement) out of phase with the cell membrane. Disruption of the LINC complex, which mechanically couples the nucleoskeleton to the cytoskeleton, doubled the magnitude of this relative motion, indicating that the nucleo-cytoskeletal configuration plays a major role in regulating nuclear motion. Consistent with a previously reported increase in nuclear stiffness caused by LIV, machine-learning-based image segmentation of confocal micrographs showed that LIV increased both apical and basal F-actin fiber numbers, generating a denser, more branched actin network near the nucleus. Following six 20 min bouts of LIV applied to MSC, RNA sequencing identified 372 differentially expressed genes. Upregulated gene sets were linked to F-actin assembly and focal adhesion pathways. Finite element simulations showed that nuclear stresses increased by LIV up to 18% were associated with nuclei flattening and a 30-50% increase in actin-generated forces. These findings demonstrate that low-intensity accelerations, independent of matrix strain, can directly activate a response of the nucleus, leading to cytoskeletal reorganization and heightened nuclear stresses. Thus, even very small oscillatory mechanical signals can markedly influence cell outcomes, establishing a mechanosensing pathway independent of extracellular strains.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nikitina, N., Wadsworth, J., Goelzer, M., Goldfeldt, M., Bursa, N., Howard, S., Crandall, C., Semodji, A., Zavala, A. G., Judex, S., Rubin, J., Lujan, T. J., Fitzpatrick, C. K., Rubin, C. T., Satici, A., Uzer, G.. 2025-04-11. Small Accelerations of the cell generate sufficient nuclear motion to modulate transcriptional activity, driving cellular response independent of matrix strain. https://doi.org/10.1101/2025.04.07.647583

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗