bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.01.24.634528

Bayesian optimization of cortical neuroprosthetic vision using perceptual feedback

Abstract

The challenge in cortical neuroprosthetic vision is determining the optimal, safe stimulation patterns for the visual cortex in order to evoke the desired perception in blind individuals--specifically, light perceptions known as phosphenes. Currently, clinical studies gain insights into the perceptual characteristics of the perceived phosphenes by asking for descriptions of provided stimulation protocols. However, the huge parameter space for multi-electrode stimulation settings makes it difficult to draw conclusions about the optimality of the stimulation patterns that lead to well-perceived phosphenes. A systematic search in the parameter space of the electrical stimulation is needed to achieve good perception. Bayesian optimization (BO) is a framework for finding optimal parameters efficiently. Using the patients scoring of the perception as feedback, a model of the patients response based on iteratively generated stimulation protocols can be built to maximize perception quality. A patient implanted with an intracortical 96-channel microelectrode array in their visual cortex was tested by iteratively presenting stimulation protocols, generated via BO for the first and random generation (RG) for the second experiment. Whereas standard BO methods do not scale well to problems with over a dozen inputs, we propose to optimize a set of 40 electrode currents using trust region-based BO. The generated protocols determine which electrodes are concurrently stimulated from the set and with how much current from a range of 0-50 {micro}A, on a maximum total current constraint of 500 {micro}A. The patient provided feedback for each stimulation based on their liking of the perception quality on a Likert scale, where a score of 7 indicated the highest quality and 0 no perception. In the BO experiment, the patient perception quality ratings gradually converged on higher values compared to the RG experiment. Similarly, gradually higher total current values were chosen by BO, in line with the observed preference of patients for higher currents due to brighter phosphenes. Finally, the electrodes that were observed to be more effective in producing phosphene perception in previous studies were gradually chosen more by BO also with the allocation of higher current values. This study demonstrates the power of BO in converging to optimal stimulation protocols based on patient feedback, providing a more efficient search for stimulation parameters for clinical studies.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kucukoglu, B., Soo, L., Leeftink, D., Grani, F., Soto Sanchez, C., Guclu, U., van Gerven, M., Fernandez, E.. 2025-01-27. Bayesian optimization of cortical neuroprosthetic vision using perceptual feedback. https://doi.org/10.1101/2025.01.24.634528

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗