bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.01.24.634528

Bayesian optimization of cortical neuroprosthetic vision using perceptual feedback

Abstract

The challenge in cortical neuroprosthetic vision is determining the optimal, safe stimulation patterns for the visual cortex in order to evoke the desired perception in blind individuals--specifically, light perceptions known as phosphenes. Currently, clinical studies gain insights into the perceptual characteristics of the perceived phosphenes by asking for descriptions of provided stimulation protocols. However, the huge parameter space for multi-electrode stimulation settings makes it difficult to draw conclusions about the optimality of the stimulation patterns that lead to well-perceived phosphenes. A systematic search in the parameter space of the electrical stimulation is needed to achieve good perception. Bayesian optimization (BO) is a framework for finding optimal parameters efficiently. Using the patients scoring of the perception as feedback, a model of the patients response based on iteratively generated stimulation protocols can be built to maximize perception quality. A patient implanted with an intracortical 96-channel microelectrode array in their visual cortex was tested by iteratively presenting stimulation protocols, generated via BO for the first and random generation (RG) for the second experiment. Whereas standard BO methods do not scale well to problems with over a dozen inputs, we propose to optimize a set of 40 electrode currents using trust region-based BO. The generated protocols determine which electrodes are concurrently stimulated from the set and with how much current from a range of 0-50 {micro}A, on a maximum total current constraint of 500 {micro}A. The patient provided feedback for each stimulation based on their liking of the perception quality on a Likert scale, where a score of 7 indicated the highest quality and 0 no perception. In the BO experiment, the patient perception quality ratings gradually converged on higher values compared to the RG experiment. Similarly, gradually higher total current values were chosen by BO, in line with the observed preference of patients for higher currents due to brighter phosphenes. Finally, the electrodes that were observed to be more effective in producing phosphene perception in previous studies were gradually chosen more by BO also with the allocation of higher current values. This study demonstrates the power of BO in converging to optimal stimulation protocols based on patient feedback, providing a more efficient search for stimulation parameters for clinical studies.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kucukoglu, B., Soo, L., Leeftink, D., Grani, F., Soto Sanchez, C., Guclu, U., van Gerven, M., Fernandez, E.. 2025-01-27. Bayesian optimization of cortical neuroprosthetic vision using perceptual feedback. https://doi.org/10.1101/2025.01.24.634528

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗