Pelvic floor disorders, including pelvic organ prolapse and stress urinary incontinence, are prevalent health concerns, affecting approximately 50% of females over their lifetime, with about 75% of women over 65 years of age being impacted. Traditional surgical interventions, such as transvaginal mesh implants, have led to numerous complications, resulting in their prohibition in several countries. This study introduces an innovative composite mesh designed to mitigate these issues by combining polymethylmethacrylate and thermoplastic polyurethane, further enhanced with iodine-doped carbon nanoparticles to enable visibility via medical imaging. The mesh is coated with 2-methacryloyloxyethyl phosphorylcholine polymer to prevent protein adsorption and promote tissue regeneration. In vitro studies showed high cell viability and low protein adsorption, indicating excellent biocompatibility. Implantation of mesh (with or without iodine) in mice revealed no adverse effects on overall animal health. Mouse spleen weight (an indicator of inflammation) was similar between groups; however, levels of some cytokines (i.e., IL-10, IL-17A and GM-CSF) were elevated following implantation of iodinated mesh in mice suggesting that further refinement of the composite mesh is required. Analysis of the fecal microbiome, which is correlated with physiological states, showed that sham and iodinated mesh implant groups maintained consistent microbial profiles with stable diversity (richness and evenness) measures over time. In contrast, the non-iodinated mesh group exhibited decreased species richness post mesh implantation, likely due to a distinct starting microbiome composition prior to implantation. This research is envisaged to contribute to a safer and more effective solution for treating pelvic floor disorders, providing non-invasive post-implantation monitoring and enhanced mechanical compatibility of surgical mesh with native tissue. Our findings demonstrate that this composite mesh possesses mechanical properties that closely mimic human tissue, ensuring biocompatibility, strength, and flexibility without stimulating significant inflammatory or foreign body responses.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Houshyar, S., Quigley, A., Cole, I., Yin, H., Zizhou, R. E., Saha, T., Pirogova, E., Yeung, J. M., Mohsenipour, M., Mirabedini, A., Subejano, E., Shindler, A. E., Wood, J. L., Franks, A. E., Hill-Yardin, E. L.. 2025-01-26. Bioengineered visible polymeric mesh to enhance urogynaecological health. https://doi.org/10.1101/2025.01.23.634411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

Population-level emulation enables fast Bayesian calibration of cardiac digital twins

Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.

bioengineering↗

Multi-Structure Segmentation of Type B Aortic Dissection from CT Images with U-Net

Type B aortic dissection (TBAD) is a life-threatening condition in which a tear in the intimal layer separates the aortic wall into a true and a false lumen. Assessment of the lumen, the intimal flap, and false-lumen thrombosis from CT images is important for risk analysis and treatment planning. This work applied U-Net-based deep neural networks to the automatic segmentation of these structures in TBAD. We collected 46 CT scans from 20 patients, with voxel-wise annotations of three structures: the aortic lumen, the intimal flap, and the thrombus. We explored four models: two convolutional networks, nnU-Net 2D and 3D, and two transformer-based architectures, TransUNet 2D and 3D. We observed that (1) for both nnU-Net and TransUNet, the 3D models outperformed their 2D counterparts on all three structures. The difference was small for the aortic lumen but large for the thin flap and the thrombus. The best model, nnU-Net 3D, reached a DSC of 93.05% for the lumen, 50.22% for the flap, and 69.94% for the thrombus. (2) The intimal flap was the most difficult structure for all models. Even the best 3D models showed large thrombus boundary errors in a few scans. These results provide a baseline for developing more advanced models for accurate segmentation of these structures in TBAD.

bioengineering↗