bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.01.17.633644

Characterization of Microbubble Cavitation in Theranostic Ultrasound-mediated Blood-Brain Barrier Opening and Gene Delivery

Abstract

RationaleThe characterization of microbubble activity has proven critical in assessing the safety and efficacy of ultrasound-mediated blood-brain barrier (BBB) opening and drug and gene delivery. In this study, we build upon our previous work on theranostic ultrasound (ThUS)-mediated BBB opening (ThUS-BBBO) and conduct for the first time a comprehensive characterization of the role of microbubble cavitation in ThUS-BBBO, as well as its impact on gene delivery with adeno-associated viruses (AAV). MethodsA repurposed imaging phased array was used throughout the study to generate focused transmits and record microbubble activity through high-resolution power cavitation imaging (PCI). The cavitation of microbubbles under ThUS pulses was first characterized in flow phantom using pulse lengths ranging from 1.5 to 20 cycles and under varying microbubble flow rates using a separate single-element transducer a passive cavitation detector (PCD). A comprehensive in vivo study in mice was then conducted to characterize the in vivo microbubble activity under ThUS and correlate the resulting cavitation with AAV-mediated transgene delivery and expression. The transcranial microbubble activity was first detected in two mice using a PCD, to confirm the findings of the flow phantom study. Next, three mouse studies were conducted to evaluate the relationship between cavitation and AAV delivery; one with three different microbubble size distributions using polydisperse and size-isolated microbubbles, one with variable burst length and burst repetition frequency, and one with different AAV serotypes and injection doses. Electronic beam steering was used to induce bilateral BBB opening with 1.5 cycle on the left and 10 cycles on the right hemisphere. Cavitation dose was correlated with BBB opening volume, AAV transgene expression was evaluated with immunofluorescence staining and histological safety was assessed with T2* imaging and Hematoxylin and Eosin staining. ResultsFrequency domain analysis in the phantoms revealed a broadband-cavitation dominance at the shorter pulse lengths, while harmonic cavitation components are significantly increased for longer pulses. The PCD was better at detecting higher frequency harmonics, while the signal received by the theranostic array was more broadband dominated. Analysis of signals in the time domain showed that the longer pulses induce higher microbubble collapse compared to short pulses. In the transcranial in vivo experiments, the PCD was able to detect increased harmonic cavitation for 10-cycle pulses. The microbubble study showed that 3-5 m microbubbles resulted in the largest cavitation doses, BBBO volumes and AAV transgene expression compared to the smaller microbubble sizes. The burst sequence study revealed that the sequences with shorter bursts and faster burst repetition frequencies induce larger BBBO volumes and AAV transduction due to faster microbubble replenishment in the focal volume. Increased erythrocyte extravasation was observed on the hemisphere sonicated with 10-cycle pulses. Transgene expression was also increased with injection dose, without notable side effects during the three-week survival period. Finally, AAV9 was shown to be the serotype with the highest transduction efficiency compared to AAV2 and AAV5 at the same injected dose. ConclusionsThis is the first comprehensive study into the microbubble cavitation under theranostic ultrasound. The phantom and in vivo studies show that the mechanism of ThUS-BBBO is mainly transient cavitation dominant, as microbubble collapse increases with pulse length despite the increased harmonic frequency response. Increased cavitation dose resulted in larger BBBO volumes and transgene expression in vivo. While ThUS induced microhemorrhage for most of the studied conditions, it did not have an impact on the survival and behavior of the mice.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tsitsos, F. N., Batts, A. J., Jimenez, D. A., Li, C., Ji, R., Bae, S., Theodorou, A., Gorman, S. L., Konofagou, E. E.. 2025-01-22. Characterization of Microbubble Cavitation in Theranostic Ultrasound-mediated Blood-Brain Barrier Opening and Gene Delivery. https://doi.org/10.1101/2025.01.17.633644

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing

Paper-based colorimetric sensors offer a low-cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing beyond wettability, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.

bioengineering↗

Engineering CAR-T cells to remodel the mucin-rich cancer cell glycocalyx

The dense glycocalyx of cancer cells can restrict immune-cell access to surface antigens and limit CAR-T cell activity. Here, we show that mucin density and epitope position determine how glycocalyx remodeling affects CAR-T cell recognition and killing. We identify KLK5 as a human protease that cleaves tumor-associated mucins, increases access to membrane-proximal antigens, and enhances CAR-T cell function. We then engineer CAR-T cells to display or secrete KLK5, enabling remodeling of the tumor glycocalyx during antigen recognition. KLK5-engineered CAR-T cells improved tumor control across multiple xenograft models, and KLK5-secreting MUC17 CAR-T cells produced the strongest in vivo benefit, prolonging survival compared with conventional MUC17 CAR-T cells. These findings show that CAR-T cells can be engineered to breach the mucin-rich glycocalyx while preserving accessible target epitopes.

bioengineering↗

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗