bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.01.17.633644

Characterization of Microbubble Cavitation in Theranostic Ultrasound-mediated Blood-Brain Barrier Opening and Gene Delivery

Abstract

RationaleThe characterization of microbubble activity has proven critical in assessing the safety and efficacy of ultrasound-mediated blood-brain barrier (BBB) opening and drug and gene delivery. In this study, we build upon our previous work on theranostic ultrasound (ThUS)-mediated BBB opening (ThUS-BBBO) and conduct for the first time a comprehensive characterization of the role of microbubble cavitation in ThUS-BBBO, as well as its impact on gene delivery with adeno-associated viruses (AAV). MethodsA repurposed imaging phased array was used throughout the study to generate focused transmits and record microbubble activity through high-resolution power cavitation imaging (PCI). The cavitation of microbubbles under ThUS pulses was first characterized in flow phantom using pulse lengths ranging from 1.5 to 20 cycles and under varying microbubble flow rates using a separate single-element transducer a passive cavitation detector (PCD). A comprehensive in vivo study in mice was then conducted to characterize the in vivo microbubble activity under ThUS and correlate the resulting cavitation with AAV-mediated transgene delivery and expression. The transcranial microbubble activity was first detected in two mice using a PCD, to confirm the findings of the flow phantom study. Next, three mouse studies were conducted to evaluate the relationship between cavitation and AAV delivery; one with three different microbubble size distributions using polydisperse and size-isolated microbubbles, one with variable burst length and burst repetition frequency, and one with different AAV serotypes and injection doses. Electronic beam steering was used to induce bilateral BBB opening with 1.5 cycle on the left and 10 cycles on the right hemisphere. Cavitation dose was correlated with BBB opening volume, AAV transgene expression was evaluated with immunofluorescence staining and histological safety was assessed with T2* imaging and Hematoxylin and Eosin staining. ResultsFrequency domain analysis in the phantoms revealed a broadband-cavitation dominance at the shorter pulse lengths, while harmonic cavitation components are significantly increased for longer pulses. The PCD was better at detecting higher frequency harmonics, while the signal received by the theranostic array was more broadband dominated. Analysis of signals in the time domain showed that the longer pulses induce higher microbubble collapse compared to short pulses. In the transcranial in vivo experiments, the PCD was able to detect increased harmonic cavitation for 10-cycle pulses. The microbubble study showed that 3-5 m microbubbles resulted in the largest cavitation doses, BBBO volumes and AAV transgene expression compared to the smaller microbubble sizes. The burst sequence study revealed that the sequences with shorter bursts and faster burst repetition frequencies induce larger BBBO volumes and AAV transduction due to faster microbubble replenishment in the focal volume. Increased erythrocyte extravasation was observed on the hemisphere sonicated with 10-cycle pulses. Transgene expression was also increased with injection dose, without notable side effects during the three-week survival period. Finally, AAV9 was shown to be the serotype with the highest transduction efficiency compared to AAV2 and AAV5 at the same injected dose. ConclusionsThis is the first comprehensive study into the microbubble cavitation under theranostic ultrasound. The phantom and in vivo studies show that the mechanism of ThUS-BBBO is mainly transient cavitation dominant, as microbubble collapse increases with pulse length despite the increased harmonic frequency response. Increased cavitation dose resulted in larger BBBO volumes and transgene expression in vivo. While ThUS induced microhemorrhage for most of the studied conditions, it did not have an impact on the survival and behavior of the mice.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tsitsos, F. N., Batts, A. J., Jimenez, D. A., Li, C., Ji, R., Bae, S., Theodorou, A., Gorman, S. L., Konofagou, E. E.. 2025-01-22. Characterization of Microbubble Cavitation in Theranostic Ultrasound-mediated Blood-Brain Barrier Opening and Gene Delivery. https://doi.org/10.1101/2025.01.17.633644

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Ferrybots: Programmable Hydrogel Microbots for Rapid Magnetic Navigation and Modular Function

Untethered microrobots could enable localized delivery, sensing, and intervention in confined biological and engineered environments. Magnetic actuation is especially attractive for such systems because it provides remote, fuel-free control, but practical magnetic microrobots remain difficult to manufacture and functionalize. High magnetic loading can interfere with polymerization and structural integrity, while integrating application-specific payloads directly into the robot body often requires the entire material formulation to be redesigned. Here, we introduce Ferrybots, programmable hydrogel microrobots that physically separate magnetic navigation from functional cargo. An automated droplet-on-demand microfluidic flow-lithography process confines high-concentration ferrofluid cores within photopolymerized poly (ethylene glycol) diacrylate (PEGDA) structures, enabling magnetic loading to be programmed through core number and spacing without uniformly dispersing magnetic particles throughout the hydrogel. The process achieved a minimum fabrication cycle time of 15 s. Ferrybots exhibited magnetic-dose-dependent translation and rotation, branched-channel steering, out-of-plane obstacle traversal, and rapid translation, with two-core robots following an external magnet at speeds up to the 9000 mm/min limit of the actuation system. Differences in magnetic loading also enabled sequential selective navigation of distinct Ferrybot populations. Using PEGDA 575 as a common interface material, independently formulated hydrogel cargo modules could subsequently be fused to preformed Ferrybots while preserving navigation. Separately, cargo modules enabled composition-dependent molecular release and oxygen-responsive sensing through 1-mm-thick skin-mimicking optical phantoms representing a broad range of skin types. By decoupling locomotion from function, Ferrybots provide a common magnetic vehicle that can be combined with interchangeable delivery, sensing, or responsive-material modules, offering a general strategy for rapidly adapting microrobots to different applications.

bioengineering↗

Circular-Arc Modal Migration for Ultrasound Imaging--Part I: Finite-Arc Spectral Theory and Stolt-Pullback Factorization

Circular-arc ultrasound imaging requires a spectral construction that accommodates radius-dependent propagation and the spatially varying phase of offset-source transmission. This first of two articles develops Circular-Arc Modal Migration (CAMM), a direct Stolt-type imaging framework in angular modal coordinates. Starting from a first-Born acoustic model, angular decomposition and local radial Stolt mappings convert channel spectra into fields for coherent image synthesis. The offset transmit phase is represented by a phase-screen factorization through reusable spectral factors and spatially weighted fields. A scalar-pullback approximation simplifies this correction to reading one reference image at a geometrically fitted radial coordinate. Both realizations share the same modal construction. Error controls address local radial synthesis, transmit-path expansion, scalar approximation, and phase-screen truncation, with direct integration verifying the separated numerical evaluation. Same-RF point-target comparisons show that scalar pullback closely preserves the principal peak positions and widths of phase-screen imaging in the compact semicircular configuration, while phase screens better control surrounding responses in the shallow convex examples. The retained modal spectrum, frequency band, image radius, and source displacement guide this accuracy--computation choice. CAMM thereby extends direct spectral image formation to circular arcs and supplies the theoretical and numerical basis for the image-quality and performance studies in Part~II.

bioengineering↗

Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls

Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.

bioengineering↗