bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.01.09.630316

Is there a pathological switch that triggers the onset of renal calcification?

Abstract

IntroductionNephrocalcinosis, nephrolithiasis and Randalls plaque formation are distinct renal pathologies of biomineralization predominantly originating in the renal papillae. Experimental evidence on the events leading to the initial aggregation of nanometer-scale plaque or stone deposits in these regions are limited. Cellular plasticity is a regulatory mechanism of disease progression, and can lead to the transition of epithelial to mesenchymal stem-cell-like phenotypes, and generate macrophages to trigger pathophysiological alterations underlying renal biomineralization. We aim to understand the pathological mechanisms of biomineralization at the renal papillary tip of clinical patient samples and develop functional assays to analyze mechanisms of disease progression within organ-chip devices in vitro. MethodsWe analyzed clinical cohorts of patient renal papillae tissues obtained via nephrectomy (n=34) categorized as stone formers (SF) vs. non-stone formers (NSF). We studied the histopathology and genetic (bulk RNA-sequencing) composition of patient samples in the two groups. We examined the role of primary cells, including peripheral blood mononuclear cells (PBMCs) - progenitors of macrophages, isolated from patient blood samples to differentiate M1 pro and M2 anti-inflammatory macrophage phenotypes for static culture and flow/stretch analyses on organ-on-a-chip devices (Emulate Inc). We stained tissue sections with histology dyes and conducted digital pathology multiplexing analyses via quantitative pathology software (quPath, GitHub) by training an artificial neural network. We conducted fluorescence in situ hybridization (FISH) studies to identify genetic biomarkers of inflammation extracted from the bulk-RNA sequencing data. ResultsBased on the initial results of digital pathology, we identified renal calcium deposits (p value = 0.0017), collagen deposits (p value = 0.0001), fibrosis (p value = 0.0385) and renal casts or inflammatory cells among SF vs NSF cohorts across the cortex-to-tip region of renal papillae. Bulk RNA-sequencing analyses were primarily conducted with DAVID-KEGG and Panther 17.0 classification databases to highlight key regulatory pathways of interest involved at the onset of renal biomineralization, such as the oxidative stress pathway, hypoxia response via HIF activation, and inflammation mediated by chemokine and cytokine signaling. The FISH studies identified genes involved with inflammation; GALNT3, PLEKHO1, SLCO2A1, and VCAM1. We successfully differentiated patient-derived PBMCs to M1 and M2 macrophage lineages to study the impact of oxidative stress by using static 35 mm plate and flow microfluidic organ-chip instruments, to conduct appropriate functional assays in cell culture. ConclusionThe study outcomes provide insights to the precursors of renal biomineralization and delineated the expression of a pathological switch at the onset of hypoxia. The data will provide a fundamental framework to isolate primary cells from patient samples to conduct cell culture studies under static conditions, and translate the outcomes to flow analyses on a Kidney Chip instrument (Emulate. Inc) to mimic pathological conditions in a microphysiological environment in vitro. The ultimate outcome of this project will lead to the development of functional assays that emulate the kidney microphysiology on an organ-chip instrument, suited for clinical translation as a personalized, precision diagnostics and therapeutics platform.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeewandara, T. M.. 2025-01-13. Is there a pathological switch that triggers the onset of renal calcification?. https://doi.org/10.1101/2025.01.09.630316

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗