bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.12.06.627297

Staying on track: collagen fibers orientation strongly affects thrombi formation at high shear

Abstract

ObjectiveSubendothelial matrix exhibits a distinctive organization, with collagen fibers beneath the endothelium oriented primarily parallel to the flow and comprising mainly types III and I collagen in arteries and arterioles. However, the significance of such organization in initiating rapid thrombus formation remains unclear. Approach and ResultsTo investigate the role of collagen fibers orientation in triggering thrombus formation we utilized the in vitro microfluidic model of thrombosis. Human whole blood was perfused through a system with collagen fibers oriented either parallel or perpendicular to the flow, and the primary stages of platelet adhesion and thrombi growth were analyzed using a high-speed fluorescence microscopy. At the shear rates of 200 and 1000 s-1 no significant difference in thrombogenicity was observed between the collagen fibers orientations. However, at a high shear rate of 2000 s-1, thrombi on the parallel fibers were higher and covered a much larger area than those on the perpendicular ones. High-speed microscopy revealed that platelets were able to achieve stable adhesion only after translocating for over several seconds under all studied conditions. Analysis of single platelets dynamics revealed that platelets interacted longer and translocated farther during their interaction with parallel fibers at high shear, suggesting that flow-aligned fibers facilitate stable adhesion by enabling platelets to translocate along them and stay in contact with collagen. Importantly, only a small fraction of collagen fibers belonging to type III collagen admixture - a common component of a standard type I collagen preparation - accumulated plasma vWF and supported platelet adhesion at high shear rate. ConclusionType III, but not type I collagen fibers oriented parallel to the flow facilitate stable platelet adhesion at high shear rates. Thus, axial orientation of subendothelial collagen fibers observed in vivo may have physiological relevance for triggering rapid thrombus formation at high shear rates. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=106 SRC="FIGDIR/small/627297v1_ufig1.gif" ALT="Figure 1"> View larger version (38K): org.highwire.dtl.DTLVardef@14c1af5org.highwire.dtl.DTLVardef@17dffceorg.highwire.dtl.DTLVardef@12548d1org.highwire.dtl.DTLVardef@cfc431_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Melnikova, J. A., Mangin, P. H., Panteleev, M. A., Nechipurenko, D. Y.. 2024-12-12. Staying on track: collagen fibers orientation strongly affects thrombi formation at high shear. https://doi.org/10.1101/2024.12.06.627297

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

A Minimally Perturbative DARPin Probe for Quantitative Fluorescence Imaging of the Human TCR-CD3 Complex

Fluorescence microscopy is a powerful tool for dissecting the molecular mechanisms of T-cell antigen recognition in living cells, but its quantitative insight critically depends on non-perturbative, high-quality probes. Here, we repurpose a small (~15 kDa) CD3epsilon-binding DARPin (designed ankyrin repeat proteins) to a fluorescent label for T-cell receptor (TCR)/CD3 complexes on primary human CD8+ T-cells, with the aim of generating a powerful tool for quantitative analysis, single-molecule tracking, and advanced imaging of TCR dynamics. We show that the DARPin binds CD3{varepsilon} with high affinity and selectivity and using single molecule tracking and brightness analysis, we characterize the TCR-CD3 diffusion behavior and show that the DARPin binds to both CD3epsilon; subunits. Importantly, labeling preserves antigen sensitivity: on supported lipid bilayers presenting cognate pMHC, T-cells remain responsive, assemble synapses, form TCR microclusters, and initiate signaling similar to unlabeled controls. We further demonstrate compatibility with lattice light-sheet microscopy for volumetric imaging of T-cell - APC interactions in living cells. Together, these results establish DARPins as versatile, minimally perturbative probes for high resolution, quantitative studies of T cell synapse organization and signaling.

biophysics↗

Monitoring intramolecular dynamics across two regions of the mouse prion protein during misfolding and oligomerization using fluorescence correlation spectroscopy

It is important to determine whether native state dynamics drive the misfolding and oligomerization of the prion protein, which are important events in prion disease, and how they are modulated by conformational conversion. Native (N) mouse prion protein (moPrP) is known to form small (OS) and large (OL) oligomers rich in {beta}-sheet, and in this study, photoinduced electron transfer-fluorescence correlation spectroscopy (PET-FCS) has been used to characterize intramolecular dynamics within individual monomeric units in both isolated OS and OL, as well as the diffusion properties of the oligomers. It is estimated that OS and OL comprise of about 15 and 55 monomeric units, respectively. Microsecond dynamics at each of the two regions that are the 1-3 and 2-3 interfaces of native protein are distinct in N, OS and OL, although they occur on very similar timescales. Analysis of the evolution of the distribution of diffusion times, determined using the maximum entropy method, indicates heterogeneity in the oligomerization reaction. Analysis of the change in the fluctuations which occur in two different timescales in the native state ensemble shows that they are damped more at the erstwhile 1-3 interface than the erstwhile 2-3 interface. The difference in the extent of damping at the erstwhile 1-3 and 2-3 interfaces can be explained on the basis of the structural changes known to occur across each region. The changes in dynamics occur concurrently in both regions, indicating that the structural changes accompanying conformational conversion also occur simultaneously during the oligomerization of moPrP.

biophysics↗

Combining CHARMM36m with OPC water improves accuracy

Atomistic simulations of intrinsically disordered proteins (IDPs) are notoriously sensitive to force field inaccuracies, either regarding the protein or the water model, yielding inaccurate observables such as compactness, secondary structure propensities, or kinetics. The currently most widely used IDP force fields are Amber99sb-disp (A99disp) and Charmm36m (C36m). A99disp includes a new water model and thus optimized both, the protein and the water interactions. In contrast, C36m used the Tip3p water model and optimized only protein interactions. In many cases, C36m+Tip3p underestimates radii of gyration compared to FRET or SAXS experiments. Such overly compact structural ensembles are believed to arise from an imbalance between protein-protein, protein-water, and water-water interactions, which might be due to Tip3p inaccuracies. Here, we aim at re-balancing these interactions by combining C36m with the Optimal Point Charge (OPC) water model. Recently, this C36m+OPC combination showed improved accuracy for the disordered domain of the measles virus nucleoprotein. Here we present a systematic assessment, comparing C36m+OPC, C36m+Tip3p, C36m+Tip4p, C22*, A03ws, A99sb-ws, and A99disp for five IDPs, as well as a subset of those for five globular proteins, a set of disordered AGQ-repeat peptides, and the fast folding miniprotein CLN025. We compared extensive MD simulations (> 8.5 ms) with SAXS, NMR, circular dichroism, photo-induced electron transfer (PET), T-jump infrared spectroscopy, and X-ray crystallography measurements. We found that combining C36m with OPC improved accuracy over C36m+Tip3p for IDP ensembles without compromising its accuracy for globular proteins. While also the kinetics of the AGQ-peptides were more accurate for C36m+OPC, those of CLN025 folding were less accurate. Overall, C36m+OPC showed similar accuracy as A99sb-ws and A99disp, the latter is currently considered among the most accurate protein force fields.

biophysics↗