Modelling inter-shot variability for robust temporal sub-sampling of dynamic, GABA-edited MR spectroscopy data

Abstract

Variability between individual transients in an MRS acquisition presents a challenge for reliable quantification, particularly in functional scenarios where discrete subsets of the available transients may be compared. The current study aims to develop and validate a model for removing unwanted variance from GABA-edited MRS data, whilst preserving variance of potential interest - such as metabolic response to a functional task. A linear model is used to describe sources of variance in the system: intrinsic, periodic variance associated with phase cycling and spectral editing, and abrupt changes associated with subject movement. We broadly hypothesize that modelling these factors appropriately will improve spectral quality and reduce variance in quantification outcomes, without introducing bias to the estimates. We additionally anticipate that the models will improve (or at least maintain) sensitivity to functional changes, outperforming established methods in this regard. In vivo GABA-edited MRS data (203 subjects from the publicly available Big GABA collection) were sub-sampled strategically to assess individual components of the model, benchmarked against the uncorrected case and against established approaches such as spectral improvement by Fourier thresholding (SIFT). Changes in metabolite concentration and lineshape simulating response to a functional task were synthesized, and sensitivity to such changes was assessed. Composite models yielded improved SNR and reduced variability of GABA+ estimates compared to the uncorrected case in all scenarios, with performance for individual model components varying. Similarly, while some model components in isolation led to increased variability in estimates, no bias was observed in these or in the composite models. While SIFT yielded the greatest reductions in unwanted variance, the resultant data were substantially less sensitive to synthetic functional changes. We conclude that the modelling presented is effective at reducing unwanted variance, whilst retaining temporal dynamics of interest for functional MRS applications, and recommend its inclusion in fMRS processing pipelines. HighlightsO_LIA novel technique for modelling unwanted variance between transients is investigated. C_LIO_LISuitable covariate models yield improved SNR and reduced variability in GABA+ estimates from the resultant spectra. C_LIO_LIExtracted spectra remain sensitive to temporal dynamics of interest for functional MRS applications. C_LI Graphical AbstractIn dynamic MRS analysis, unwanted variability between transients may confound findings when sub-sampling within a single acquisition. We investigate covariate models and lineshape matching strategies to address this. We present composite models yielding improved quality metrics and within-scan repeatability while maintaining sensitivity to (synthetic) functional changes. O_FIG O_LINKSMALLFIG WIDTH=171 HEIGHT=200 SRC="FIGDIR/small/627018v1_ufig1.gif" ALT="Figure 1"> View larger version (48K): org.highwire.dtl.DTLVardef@174334forg.highwire.dtl.DTLVardef@1d4a500org.highwire.dtl.DTLVardef@19ce283org.highwire.dtl.DTLVardef@db2a29_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Craven, A. R., Ersland, L., Hugdahl, K., Gruner, R.. 2024-12-09. Modelling inter-shot variability for robust temporal sub-sampling of dynamic, GABA-edited MR spectroscopy data. https://doi.org/10.1101/2024.12.05.627018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗