bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.10.30.621107

HMGB1 mediates macrophage recruitment and regional intervertebral disc tissue functional and mechanical property changes following injury.

Abstract

ObjectiveFrequently evaluated in musculoskeletal disease, damage associated molecular patterns (DAMPs) respond to tissue damage and cellular stress by facilitating an inflammatory response via macrophage activation and broad inflammatory pathway activation. In the context of disc degeneration (DD), high mobility group box 1 (HMGB1), a potent intracellular DAMP, is seen to be increased within severely degenerated human IVDs and to directly mediate inflammatory responses within disc cells in vitro. To further understand how HMGB1 mediated inflammation influences DD, this study evaluated the possible protective effect of an HMGB1 knockout on DD pathology following injury. MethodsUsing a needle puncture injury model in murine caudal IVDs we evaluated DD pathology within an IVD specific Hmgb1 knockout (KO) model. Structural and compositional changes in IVD cellularity, histopathology, disc height, and biomechanics were evaluated in addition to an assessment of disc inflammation via gene expression and macrophage presence throughout the course of degeneration. ResultsHMGB1 expression robustly increased shortly following needle puncture injury and elevated levels were sustained up to 28-days post injury both in injured IVDs and in the IVDs adjacent to the level of injury. IVD specific Hmgb1 KO mice had an increased disc height following injury both at the injured and adjacent to injury level compared to injured WT IVDs. Hmgb1 KO also protected against tissue mechanical property losses at both the injured (dynamic modulus) and adjacent to injury level (dynamic modulus, creep, and equilibrium modulus) compared to injured WT IVDs, however there was no significant effect on histopathologic scores post injury. Hmgb1 KO resulted in alterations in macrophage (F4/80+) recruitment to the IVD post injury in vivo. A lower macrophage migration was also observed in vitro in response to the secretome of an injured Hmgb1 KO IVD compared to injured WT IVDs. Hmgb1 KO had no effect on inflammatory gene expression changes following injury within adjacent to injury level or injury level IVDs. ConclusionOverall findings indicate that HMGB1 is upregulated regionally, at both the injured level and at the level adjacent to injury. Results suggest that HMGB1 plays a role in mediating structural, biomechanical, and inflammatory responses to IVD injury and serves as a potent chemoattractant, mediating macrophage recruitment to the IVD and overall migratory function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Burt, K. G., Kim, M. K. M., Viola, D. C., Genualdi, J. R., Marciano, G. F., Chahine, N. O.. 2024-11-03. HMGB1 mediates macrophage recruitment and regional intervertebral disc tissue functional and mechanical property changes following injury.. https://doi.org/10.1101/2024.10.30.621107

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗