bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.10.02.615399

Microplate micromilling: A customizable platform to support the prototyping, development and testing of microphysiological culture models

Abstract

The development of microphysiological cell culture models (MPMs) that align with the throughput demands of drug and chemical testing are needed to help reduce animal testing, aide in the discovery of new drugs, and identify harmful chemical exposures. To address this need, we have developed a process for rapid prototyping MPM devices using computer numerical control (CNC) micromilling of commercially available microplates. Microchannels are cut out of the existing microplate structure and ports are drilled into the bottom of the wells to interface the wells. To test versatility and benchmark to another rapid-prototyping approach, we manufactured common microfluidic features into microplates using four different CNC mills as well as a 3D printer. Cell viability was assessed for polystyrene (PS) well plates and two 3D printed resins (MED610 and VeroClear) with the PS showing >2.5-fold increase in cell growth after three days. Machines were tested on their ability to create common device features including a traditional microfluidic device as well as a custom design incorporating complex geometries. Features were measured by confocal microscopy. We found that features including 1000{micro}m ports, 800{micro}m microchannels, 200{micro}m phase-guides, and 500{micro}m post arrays were machined and the range of CVs for features were 1.02-4.42, 1.32-3.50, 2.34-16.58, 6.25-16.40 respectively, while the 3D printed features exhibited maximal CVs of 20.98, 11.68, 23.60, and 10.01 for the same features. Predictably, more expensive machines generally showed higher accuracy and lower variation, but many features could be created accurately and precisely by inexpensive (<$3000) machines facilitating the broader use of this technology to create a user customizable platform to support the prototyping, development, and testing of human relevant models with broad applications across the life sciences. Graphical abstractMultiple CNC mills are assessed on accuracy and precision of microfluidic features of interest for microphysiological model development creation. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=112 SRC="FIGDIR/small/615399v1_ufig1.gif" ALT="Figure 1"> View larger version (42K): org.highwire.dtl.DTLVardef@1be08eorg.highwire.dtl.DTLVardef@33b0a4org.highwire.dtl.DTLVardef@192167borg.highwire.dtl.DTLVardef@200b7_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Reynolds, J. I., Adams, M., Jimenez, J., Johnson, B. P.. 2024-10-03. Microplate micromilling: A customizable platform to support the prototyping, development and testing of microphysiological culture models. https://doi.org/10.1101/2024.10.02.615399

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Selected for the surface: adaptive laboratory evolution for accelerated cathodic biofilm development in Cupriavidus necator

Cupriavidus necator is a metabolically versatile facultative chemolithoautotroph and a promising chassis for sustainable bioproduction from CO2. Efficient coupling of its metabolism to renewable electricity through microbial electrosynthesis (MES) requires the organism to form stable, electroactive biofilms on cathodes. This step is hindered under oxic conditions (oxic MES, oMES) by electrochemically generated reactive oxygen species (ROS), mass-transfer limitations and poor biofilm stability. Systematic strategies to improve C. necator biofilm formation on cathodes have been lacking. Here we used adaptive laboratory evolution (ALE) to address this gap. The progenitor strain colonised graphite cathodes only after an initial heterotrophic phase and formed spatially uneven biofilms whose distribution mirrored the local flow field, as resolved by micro-particle tracking velocimetry. Populations were then selected over five passages under controlled, oxygen-limited cathodic conditions. Resequencing revealed that the recovered population was genetically heterogeneous, and its dominant isolate, strain 890, was characterised in a microfluidic oMES platform. Strain 890 reached the target electrode coverage in about one day instead of six and maintained a robust biofilm at the progenitor's steady-state biovolume, whereas the multi-strain pool peaked higher but proved unstable. Relative to the progenitor, the accelerated biofilm phenotype of strain 890 is driven by a single novel mutation in a bifunctional diguanylate cyclase/phosphodiesterase locus, which likely encodes a central regulator of the planktonic-to-biofilm transition. The steady-state biovolume itself remained bounded, most probably due to a mass-transfer ceiling set by the counter-directional supply of H2 and O2. This work shows that ALE renders the initial-attachment barrier of cathodic biofilm formation genetically tractable, providing strain 890 as a robust chassis and a well-defined starting point for oMES-based CO2 valorisation.

bioengineering↗

Engineering a High-Fidelity CRISPR-Cas13d System for Targeted RNA Depletion in Plasmodium falciparum

Functional genomics in Plasmodium falciparum is severely constrained by the evolutionary absence of an endogenous RNA interference pathway and the requirement for time-consuming direct target locus modification by conventional conditional genetic engineering systems. To overcome these limitations, we established a programmable post-transcriptional gene silencing system in P. falciparum using High-Fidelity RfxCas13d (HF-RfxCas13d), an RNA-guided RNA nuclease that has been previously tested in several eukaryotic hosts. Using CRISPR-SpyCas9 we integrated a HF-RfxCas13d expression cassette at the dispensable pfs47 locus and generated a stable marker-free transgenic line capable of constitutive HF-RfxCas13d cytosolic expression without impairing intraerythrocytic asexual growth. Episomal delivery of single or dual guide RNAs (gRNAs) achieved significant target mRNA depletion (41%-76%) across three endogenous loci atp4, ap2-exp, ap2-g genes. Applying this system to the master transcriptional regulator of gametocytogenesis (ap2-g) resulted in transcript depletion that functionally impaired sexual differentiation in committed parasites, reducing significantly the Sexual Conversion Rate a 70%. Overall, our novel HF-Cas13d line provides a flexible, scalable, and non-locus-modifying addition to the P. falciparum genetic toolbox to accelerate functional genomics and malaria drug target identification.

bioengineering↗

DECODE: DEcomposition of COupled and DEcoupled Brain States: Separating Structure-Coupled and Structure-Decoupled Functional Organization in Alzheimers Disease

Brain functional activity emerges within an underlying structural scaffold. While structural network connectivity provides a relatively stable anatomical backbone for large-scale communication, functional interactions are high-dimensional and temporally dynamic, forming recurrent patterns that can be represented in a latent space of transient functional states. Yet, how these transient functional states are organized and the extent to which they remain constrained by structural network connectivity or become relatively decoupled from structural organization over time remain poorly understood. To address this gap, we introduce DECODE (DEcomposition of COupled and DEcoupled Brain States), a data-driven latent-space framework that uses independent component analysis (ICA) and multimodal data to decompose resting-state dynamic functional network connectivity into a lower-dimensional representation of transient functional states. These states capture temporally varying structure-coupled and structure-decoupled patterns using diffusion MRI-derived structural network connectivity priors. Structure-coupled states reflect functional configurations more strongly anchored to major structural motifs, whereas structure-decoupled states represent configurations less constrained by the identified structural organization, while potentially remaining within structurally defined dynamical bounds. DECODE identifies reproducible structure-coupled and structure-decoupled states, with mean squared error reconstruction of dynamic information < 0.1 and adjusted R-squared = 0.4. Applied to Alzheimers disease (AD), DECODE revealed stronger group differences (FDR-corrected p-value 0.05) in both connectivity organization and temporal dynamics for decoupled states. These findings suggest that functional states less constrained by identified structural organization may be more vulnerable to AD-related disruption, whereas structure-coupled states may be relatively preserved. More broadly, DECODE provides a reproducible and generalizable framework for quantifying how functional dynamics are shaped by, or diverge from, structural organization by incorporating a latent representation of the structural connectome as an informative prior. Our findings established structural and functional alignment variation by distinguishing dynamic functional patterns closely coupled with structure from those that deviate from it.

bioengineering↗