bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.08.09.607349

Simplified and Rapid Workflow Enhances Throughput of De Novo Sequencing of COVID-19 Neutralizing Antibodies

Abstract

During the current COVID-19 pandemic, precise antibody sequencing is crucial for the rapid development of broad-spectrum or pan-{beta}-coronavirus neutralizing antibodies (NAbs) to prevent new variants of the coronavirus and other highly pathogenic {beta}-coronaviruses. However, mass spectrometry-based de novo sequencing remains challenging due to its high cost, low throughput, and unexpected missing of certain ion information. We developed an innovative approach using solely bottom-up to provide a rapid, robust, and refined solution for the current de novo sequencing challenges. The methodology, referred to as SP-MEGD for Single-Pot and Multi-Enzymatic Gradient Digestion, capitalizes on a five-protease gradient digestion by sampling every two hours for a total of 6 hours in an integrative reactor. The SP-MEGD method could engender numerous missed cleavage events and produce various peptide products of diverse lengths with overlapping stretches of residues, enabling efficient database-free de novo sequencing. Antibody assembly for single or mixed COVID-19-NAbs with publicly available sequences and commercial antibodies with unknown sequences was efficiently deciphered using our previously proposed optimization method, Fusion assembler. Our innovative study represents the first successful simultaneous discrimination and achieving over 99% accurate sequence coverage of a mixture containing three humanized COVID-19-NAbs (S2P6LH, BD5514LH, and BD5840LH). Furthermore, we utilized SP-MEGD and Fusion to sequence commonly used anti-CD8 and anti-CD4, and successfully confirmed their impact on immune cell clearance through in vivo experiments. Overall, our developed workflow demonstrates promise in facilitating the discovery and development of vaccines and antibody therapeutics while providing deeper insights into monoclonal antibodies (mAbs).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xiong, Y., Xiao, J., Jiang, W., Wang, J., Bu, Q., Chen, X., Wu, Y., Yu, R., Yuan, Q., Xia, N.. 2024-08-12. Simplified and Rapid Workflow Enhances Throughput of De Novo Sequencing of COVID-19 Neutralizing Antibodies. https://doi.org/10.1101/2024.08.09.607349

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

SpiraMed: A Stereotactic Helix-based Therapy Delivery system for the Human Brain

Stereotactic needle-based delivery remains the standard for local administration of Advanced Therapy Medicinal Products (ATMPs) to the human brain. ATMP administration typically involves multiple trajectories, presenting cumulative risks and prolonging surgery. Reflux-prone, patchy therapy coverage compromises clinical results. We demonstrate a novel approach, deploying a helical delivery catheter via a single access trajectory per target, referred to as SpiraMed. Helix retraction is synchronised with therapy delivery, enabling comprehensive target coverage in seconds. Helix pitch and diameter can be precisely tailored to patient-specific target volume and vascular anatomy, as part of the preoperative stereotactic surgical planning process. Testing in agarose phantoms, live sheep and cadaveric human brain confirms enhanced therapy delivery volume, delivery speed and target coverage, with reductions in reflux and predicted risk of bleeding complication. SpiraMed represents a new paradigm, promising to help deliver on the transformative potential of cell and gene therapies across the spectrum of human CNS disease.

bioengineering↗

Normative Modeling of Molecular-Enriched Functional Connectivity for Detecting Deviations from Healthy Brain Aging

Inter-individual variability in adult brain aging can obscure early pathological alterations and is only partly represented by population-average or scalar brain-aging measures. We combined Receptor-Enriched Analysis of functional Connectivity by Targets (REACT) with normative modeling (NM) to derive spatially resolved, molecularly informed deviation scores for dopamine transporter (DAT)-, norepinephrine transporter (NET)-, and serotonin transporter (SERT)-enriched resting-state functional connectivity (FC). We first evaluated whether these normative models could be transferred to independently processed external data through local calibration and then explored whether the resulting deviation profiles differed with cerebral amyloid burden in cognitively unimpaired older adults. Hierarchical Bayesian regression (HBR) models with a SHASHb likelihood were estimated separately for 204 cortical molecular-enriched FC features in 4,152 healthy adults (18.0--89.8 years) from seven publicly available neuroimaging datasets and evaluated in a held-out healthy test set. Pretrained models were locally adapted to three AMYPAD-PNHS acquisition batches using cognitively unimpaired, amyloid-negative participants (global Clinical Dementia Rating [CDR] = 0; Centiloid [CL] [lt] 10). The independent primary comparison contrasted participants with intermediate amyloid burden (10 [≤] CL [lt] 30; n = 111) and amyloid-positive participants (CL [≥] 30; n = 66); secondary analyses tested linear associations with continuous CL within participants with CL [≥] 10. Of 204 normative reference models, 199 (97.5%) met the predefined diagnostic criteria; median held-out explained variance (EXPV) was 0.174. Of 612 feature-by-batch transfers, 541 (88.4%) met the strict transfer-diagnostic criteria. In the primary false discovery rate (FDR)-controlled regional analysis, DAT-enriched right caudal middle frontal cortex showed lower locally standardized deviation scores in the intermediate-amyloid-burden group than in the amyloid-positive group (adjusted difference = -0.582, q = 0.016). DAT extreme-deviation burden was also greater in the intermediate-amyloid-burden group (difference = 0.032, q = 0.044). The right frontal effect was reproduced with model-native scores across the three acquisition batches (pooled standardized effect = -0.698, q = 0.010). No NET- or SERT-enriched regional difference between these two groups survived FDR correction, and no regional or subject-level linear association with continuous CL values survived FDR correction in the CL [≥] 10 group. Normative modeling can provide spatially resolved reference distributions of molecular-enriched FC that are deployable in independently processed external data when local adaptation, calibration, and feature-level transfer diagnostics are incorporated. The AMYPAD-PNHS application identified modest, spatially selective, and molecular-system-specific categorical differences during a cognitively unimpaired stage of amyloid accumulation, while continuous analyses within CL [≥] 10 did not support a linear association. These findings support a methodological basis for distributed application of molecular-enriched normative models and motivate independent and longitudinal evaluation of their biological relevance.

bioengineering↗

AC-Diff: Anatomy-Contrast Disentangled Diffusion for Multi-Vendor Liver MRI Harmonization

Magnetic resonance imaging (MRI) exhibits substantial scanner and protocol dependent appearance variations, making harmonization challenging without distorting patient specific anatomy, particularly in abdominal imaging. We propose AC-Diff, an anatomy--contrast disentangled diffusion framework that formulates MRI harmonization as a factor-specific generative intervention. Using aligned multi-contrast supervision and cross-patient factor swapping, AC-Diff learns to separate anatomical structure from acquisition-dependent contrast. Unlike conventional image or latent diffusion, AC-Diff restricts stochastic generation to the contrast subspace while the source anatomy bypasses diffusion and is directly reused during reconstruction. Experiments on an in-house multi-vendor cohort and the external Duke Liver MRI dataset demonstrate improved target-domain alignment with strong structural preservation. In downstream liver segmentation, AC-Diff improves Dice from 0.942 for the original inputs to 0.954 for the harmonized images. These results support contrast-specific latent generation as a promising approach to anatomy-preserving MRI harmonization.

bioengineering↗