bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.06.12.598739

Personalizing a computational upper body model improves kinematic tracking in high range-of-motion arm movements

Abstract

Musculoskeletal models of the shoulder are needed to understand the mechanics of overhead motions. Existing models can be scaled to represent the size of an individual person, but the kinematics are generic. We introduce a method to personalize the shoulder kinematics of a computational model of the upper body that defines the orientations of the clavicle and scapula based on glenohumeral joint angles. During five static calibration poses, we palpate and measure the orientation of the scapula. We explore the importance of representing shoulder elevation by introducing clavicle elevation as a degree of freedom that is independent of the glenohumeral angles. For ten subjects, we record the five calibration poses, ten additional static poses, and dynamic arm raises using optical motion capture. We examine the data using a dynamically-constrained inverse kinematics analysis. Personalization, independent clavicle elevation, and both in combination reduce the average upper body marker tracking error compared to the generic model in the static poses (26 mm to 17-20 mm) and in the dynamic trials (22 mm to 14-17 mm). Only personalization reduces the average scapula marker error (51 mm to 36-38 mm) and scapula axis-angle error (15{degrees} to 10{degrees}) in the static poses, and in the dynamic trials at instances that best match the static poses (53 mm to 37-40 mm, 15{degrees} to 9{degrees}). Our results show that personalizing upper body models improves kinematic tracking. We provide our experimental data, model, and methods to allow researchers to reproduce and build upon our results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Maier, J. N., Bianco, N. A., Ong, C., Muccini, J., Kuhl, E., Delp, S.. 2024-06-14. Personalizing a computational upper body model improves kinematic tracking in high range-of-motion arm movements. https://doi.org/10.1101/2024.06.12.598739

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗