bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.04.16.589690

Prediction of acoustic tinnitus suppression using resting state EEG: An explainable AI approach

Abstract

Tinnitus, characterized by the perception of sound without an external source, affects a significant portion of the population and can lead to considerable individual suffering, yet understanding of its suppression remains limited. Understanding neural traits of tinnitus suppression may be crucial for developing accurate predictive models in tinnitus research and treatment. This study aims to classify individuals capable of brief acoustic tinnitus suppression (BATS; also known as residual inhibition) based on their independent resting state EEG (n=102), exploring the classifications robustness on various sample splits, and the relevance of resulting specific EEG features in the spirit of explainable AI. A comprehensive set of EEG features, including band power in standard frequency bands, spectral entropy, aperiodic slope and offset of the power spectrum, and connectivity, was included in both sensor and source space. Binary classification of the BATS status was performed using a comprehensive set of standard classifiers and Pearson correlation for feature selection, which addresses multicollinearity, avoiding complex dimensionality reduction techniques. Feature importance was assessed using Gini impurity metrics, allowing interpretation of the directionality of identified neural features. The Random Forest model showed the most consistent performance, with its majority voting mechanism effectively reducing overfitting and providing reliable predictions, and was therefore chosen for subsequent feature interpretation analysis. Our classification task demonstrated high accuracy across the various BATS split thresholds, suggesting that the choice of threshold does not significantly influence the underlying pattern in the data. We achieved classification accuracies of 98% for sensor and source models and 86% for the connectivity model in the main split. Looking at identified important features, our findings align with and extend existing neuroscience research in tinnitus by discovering highly specific and novel neural features in naive resting-state data predictive of BATS. Gamma power is identified as the most important feature in the sensor model, followed by alpha power, which fits current models of sensory processing, prediction, and updating (gamma) as well as inhibitory (alpha) frameworks. The overall spectral shape of the EEG power spectrum tends to be more normal in +BATS individuals, as reflected in the aperiodic offset and slope features. In the source model, important features are lateralized in that the gamma feature is more prominent in the left core auditory network, whereas the alpha feature is distributed more sparsely over the right hemisphere in line with auditory attention data. Furthermore, we identified several hotspots in the temporal, insular, parietal, parahippocampal, medial prefrontal, and (posterior) cingulate cortex implicated in sensory processing, gating, attention, and memory processes. Relevant network features were found in a hyperconnected bilateral auditory network (within the network), while the full auditory network was hyperconnected to limbic regions (between networks), which may reflect an intact sensory gating mechanism aiding tinnitus suppression. This studys implications extend to improving the understanding and prediction of tinnitus loudness perception and tinnitus distress as well as its (acoustic) suppression. Furthermore, our approach underscores the importance of careful feature selection, model choice, and validation strategies in analyzing complex neurophysiological data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sadeghi Shabestari, P., Schoisswohl, S., Wellauer, Z., Naas, A., Kleinjung, T., Schecklmann, M., Langguth, B., Neff, P.. 2024-04-19. Prediction of acoustic tinnitus suppression using resting state EEG: An explainable AI approach. https://doi.org/10.1101/2024.04.16.589690

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗