Soft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis

Abstract

INTRODUCTIONImprovement in diagnostic and surgical techniques in hip arthroscopy have led to a surge in hip distraction procedures over the recent years with the predicted annual frequency being four out of every 10,000 orthopedic procedures in 2017. Due to the large traction force required to achieve the appropriate joint spacing intra-operatively, an emergence of traction-related neurological and soft tissue injuries have surfaced. Pre-existing hip joint pathologies and surgical procedures disrupt the biomechanical stability of the joint and significantly increase the risk of iatrogenic damage. Furthermore, patients with total knee arthroplasties are often subject to intra-articular ligament releases, leading to reduced stability; however, it is not well understood how this may impact their outcomes of hip arthroscopic procedures. The current study aims to investigate the biomechanical behavior of various instrumented knee joints subjected to traction forces to aid clinical understanding and advancements of hip arthroscopy techniques. METHODSA validated finite element (FE) model of the pelvis and lower extremity was developed from computed tomography (CT) scans of a healthy 45-year-old female. Three different models were assembled according to different TKA techniques performed: Bi-Cruciate Retaining (BCR) model, Posterior-Cruciate Retaining (PCR) model, and Posterior Stabilized (PS) model. The BCR model is noted by retaining all native ligaments of the knee joint (ACL, PCL, MCL, and LCL), whereas the PCR model was subject to ACL removal and the PS model required ACL and PCL removal (Figure 1). The pelvis was encastered to prevent translation under the traction forces as motion of the patients trunk is restrained, intraoperatively. To simulate the loading condition of hip distraction, an axial force was coupled to the distal fibula and tibia and incrementally increased from 100N to 500N. Joint spacing and ligament strain in the hip and knee joint were analyzed to assess the effects of traction forces. O_FIG O_LINKSMALLFIG WIDTH=174 HEIGHT=200 SRC="FIGDIR/small/580129v2_fig1.gif" ALT="Figure 1"> View larger version (70K): org.highwire.dtl.DTLVardef@1494014org.highwire.dtl.DTLVardef@e0fdeorg.highwire.dtl.DTLVardef@133cb56org.highwire.dtl.DTLVardef@16aaf02_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 1.C_FLOATNO Meshed parts of the A.) Posterior Cruciate retaining total knee replacement system and the B.) Bi-cruciate retaining total knee replacement system. C_FIG RESULTSThe medial and lateral compartment stiffness of the knee joint was analyzed under hip distraction for the three different TKA scenarios. The BCR model displayed the greatest average knee complex stiffness. Release of the ACL resulted in a larger decrease of stiffness compared to release of the PCL. There was no change in forces required for hip distraction as result of changes in the knee joint stiffness (Figure 3). The PCR and PS models were subject to excess knee joint distraction that exceeded 12 mm and ligament strain greater than 20% before adequate hip joint distraction of 10 mm was achieved. The BCR model remained below 10 mm of knee distraction and 15% ligament strain at 10 mm of hip joint distraction. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=182 SRC="FIGDIR/small/580129v2_fig3.gif" ALT="Figure 3"> View larger version (90K): org.highwire.dtl.DTLVardef@107c292org.highwire.dtl.DTLVardef@77351corg.highwire.dtl.DTLVardef@40011aorg.highwire.dtl.DTLVardef@88e9c_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 3.C_FLOATNO FE models of instrumented TKA. A) PCR TKA with simulated ACL release. B) PS TKA with simulated ACL and PCL releases. C) BCR TKA with intact ligaments. C_FIG DISCUSSIONOur study reveals patients undergoing hip distraction with a prior TKA may experience increased soft tissue damage or iatrogenic dislocation due to reduced knee joint stability. The PCR and PS models outline a trend suggesting patients who have undergone ligament sacrificing TKAs experience large reductions in knee joint stability, causing strain levels that are indicative of soft tissue injury. The BCR TKA was indicated to be the safest under the distraction conditions as joint spacing and strain levels were largely reduced comparatively; however, when surpassing 10 mm of knee joint distraction at forces greater than 350 N, the strain levels in the ACL suggest minor injury may occur.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Soehnlen, S. M., Sadeqi, S., Kumaran, Y., Tripathi, S., Jones, R. K., Sohn, D. H., Goel, V. K.. 2024-02-16. Soft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis. https://doi.org/10.1101/2024.02.13.580129

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗