bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.01.26.577474

Polycaprolactone-based shape memory foams as self-fitting vaginal stents

Abstract

There is an urgent critical need for a patient-forward vaginal stent that can prevent debilitating vaginal stenosis that occurs in up to 75% of patients who undergo pelvic radiation treatments and adolescent patients after vaginal reconstruction. To this end, we developed a self-fitting vaginal stent based on a shape-memory polymer (SMP) foam that can assume a secondary, compressed shape for ease of deployment. Upon insertion, the change in temperature and hydration initiates foam expansion to shape fit to the individual patient and restore the lumen of the stent to allow egress of vaginal secretions. To achieve rapid actuation at physiological temperature, we investigated the effect of architecture of two photocurable, polycaprolactone (PCL) macromers. Star-PCL-tetraacrylate displayed reduced melting temperature in the target range as compared to the linear-PCL-diacrylate. Emulsion-templating was then used to fabricate foams from 75:25 water-in-oil (W/O) emulsions that were subsequently annealed to yield high-porosity SMP foams. Upon axial shape memory testing, both foams displayed excellent shape fixity (90%); however, only the PCL star-foams displayed shape recovery ([~]84%) at 37{degrees}C to its permanent shape. A custom mold and curing system was then used to fabricate PCL star- foams into hollow, cylindrical stents. The stent was crimped to its temporary insertion shape (50% reduction in diameter, OD [~] 11 mm) with a custom radial crimper and displayed excellent shape fixity for deployment (> 95%) and shape recovery ([~] 100%). To screen vaginal stents, we developed a custom benchtop pelvic model that simulated vaginal anatomy, temperatures, and pressures with an associated computational model. A hysteroscope was used to visualize stent expansion and deformation via a scope port near the cervix of the benchtop model. A crimped SMP vaginal stent was deployed in the model and expanded to walls of the canal ([~]70% increase in cross-sectional area) in less than 5 minutes after irrigation with warm water. The vaginal stent demonstrated retention of vaginal caliber with less than 1% decrease in cross-sectional area under physiological pressure. Collectively, this work demonstrates the potential for SMP foams as self-fitting vaginal stents to prevent stenosis. Additionally, this work provides new open-source tools for the iterative design of other gynecological devices. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=87 SRC="FIGDIR/small/577474v1_ufig1.gif" ALT="Figure 1"> View larger version (37K): org.highwire.dtl.DTLVardef@1bc3162org.highwire.dtl.DTLVardef@4e5657org.highwire.dtl.DTLVardef@1069d33org.highwire.dtl.DTLVardef@13aa9da_HPS_FORMAT_FIGEXP M_FIG C_FIG Created in BioRender

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hicks, A. J., Roberts, C., Robinson, A., Wilson, K., Kotamreddy, V., LaRue, T., Veyssi, A., Beltran, F., Hakim, J., Rausch, M. K., Grunlan, M., Cosgriff-Hernandez, E.. 2024-01-30. Polycaprolactone-based shape memory foams as self-fitting vaginal stents. https://doi.org/10.1101/2024.01.26.577474

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗