bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.01.06.574467

Development and validation of a subject-specific integrated finite element musculoskeletal model of human trunk with ergonomic and clinical applications

Abstract

Background and ObjectivesBiomechanical modeling of the human trunk is crucial for understanding spinal mechanics and its role in ergonomics and clinical interventions. Traditional models have been limited by only considering the passive structures of the spine in finite element (FE) models or incorporating active muscular components in multi-body musculoskeletal (MS) models with an oversimplified spine. This study aimed to develop and validate a subject-specific coupled FE-MS model of the trunk that integrates detailed representation of both the passive and active components for biomechanical simulations. MethodsWe constructed a parametric FE model of the trunk, incorporating a realistic muscle architecture, personalized through imaging datasets and statistical shape models. To validate the model, we compared tissue-level responses with in vitro experiments, and muscle activities and intradiscal pressures versus in vivo measurements during various physical activities. We further demonstrated the versatility of the proposed personalized integrated framework through additional applications in ergonomics (i.e., wearing an exoskeleton) and surgical interventions (e.g., nucleotomy and spinal fusion). ResultsThe model demonstrated satisfactory agreement with experimental data, showcasing its validity to predict tissue- and disc-level responses accurately, as well as muscle activity and intradiscal pressures. When simulating ergonomics scenarios, the exoskeleton-wearing condition resulted in lower intradiscal pressures (1.9 MPa vs. 2.2 MPa at L4-L5) and peak von Mises stresses in the annulus fibrosus (2.2 MPa vs. 2.9 MPa) during forward flexion. In the context of surgical interventions, spinal fusion at L4-L5 led to increased intradiscal pressure in the adjacent upper disc (1.72 MPa vs. 1.58 MPa), whereas nucleotomy minimally influenced intact disc pressures but significantly altered facet joint loads and annulus fibrosus radial strains. ConclusionsThe integrated FE-MS model of the trunk represents a significant advancement in biomechanical simulations, providing insights into the intricate interplay between active and passive spinal components. Its predictive capability extends beyond that of conventional models, enabling detailed risk analysis and the simulation of varied surgical outcomes. This comprehensive tool has potential implications for the design of ergonomic interventions and the optimization of surgical techniques to minimize detrimental effects on spinal mechanics.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ghezelbash, F., Eskandari, A. H., Shirazi-Adl, A., Lariviere, C.. 2024-01-08. Development and validation of a subject-specific integrated finite element musculoskeletal model of human trunk with ergonomic and clinical applications. https://doi.org/10.1101/2024.01.06.574467

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗