bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.12.15.569064

Bioactive coatings on 3D printed polycaprolactone scaffolds for bone regeneration: a novel murine femur defect model for examination of the biomaterial capacity for repair.

Abstract

Bone tissue engineering is a rapidly advancing field that seeks to develop efficacious approaches for treating non-healing fractures and large bone defects. Healing complications arise due to trauma, disease, infection, aseptic loosening of orthopaedic implants or iatrogenic causes. An ideal biodegradable scaffold would induce and support bone formation until the bone matrix is sufficiently stable to facilitate healing. The current study has examined bone augmentation, using functionalised coated scaffolds, with the hypothesised potential to induce skeletal cell differentiation for the repair of critical-sized bone defects. However, challenges in clinical translation arise from the alterations in cellular microenvironment that are present in the translation from in vitro to in vivo with the application of animal models of progressively increasing size and complexity of the implantation site. 3D printed, porous poly(caprolactone) trimethacrylate (denoted PCL-TMA900) scaffolds were applied within a murine femur defect, stabilised by a polyimide intramedullary pin, to assess the efficacy of select coatings in inducing bone formation. The PCL-TMA900 scaffolds were coated with i) elastin-like polypeptide (ELP), ii) poly(ethyl acrylate)/fibronectin/bone morphogenetic protein-2 (PEA/FN/BMP-2), iii) both ELP and PEA/FN/BMP-2 concurrently, or iv) Laponite nanoclay binding BMP-2, as bioactive coatings. The murine femur defect model was refined to assess the coated PCL-TMA900 scaffolds in an osseous defect, with sequential microcomputed tomography ({micro}CT) and histological analysis of the new bone tissue. Overall, PCL-TMA900 was found to be an optimal robust, biocompatible, 3D printable scaffold material. All PCL-TMA900 scaffolds, uncoated and coated, showed integration with the femur. The PCL-TMA900 scaffold coated with the nanoclay material Laponite and BMP-2 induced consistent, significant bone formation compared to the uncoated PCL-TMA900 scaffold. Bone formation was observed within the pores of the Laponite/BMP-2 coated scaffold. Critically, no heterotopic bone formation was observed as the BMP-2 was retained around the scaffold and not released into the tissues, producing bone around the scaffold in the desired shape and volume, compared to bone formation observed with the positive control (collagen sponge/BMP-2 construct). In comparison, the ELP coated and PEA/FN/BMP-2 scaffolds did not demonstrate significant or consistent bone formation compared to uncoated PCL-TMA900 control scaffolds. In summary, nanoclay Laponite/BMP-2 coated PCL-TMA900 scaffolds offer a biodegradable, osteogenic construct for bone augmentation with potential for development into a large scale polymer scaffold for translation to the clinic.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Marshall, K. M., Wojciechowski, J. P., Jayawarna, V., Hasan, A., Echalier, C., Callens, S. J. P., Yang, T., Kanczler, J. M., Dawson, J. I., Mata, A., Salmeron-Sanchez, M., Stevens, M. M., Oreffo, R. O. C.. 2023-12-15. Bioactive coatings on 3D printed polycaprolactone scaffolds for bone regeneration: a novel murine femur defect model for examination of the biomaterial capacity for repair.. https://doi.org/10.1101/2023.12.15.569064

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗