Abstract

Brain-Computer Interfaces (BCI) aim to establish a pathway between the brain and an external device without the involvement of the motor system, relying exclusively on neural signals. Such systems have the potential to provide a means of communication for patients who have lost the ability to speak due to a neurological disorder. Traditional methodologies for decoding imagined speech directly from brain signals often deploy static classifiers, that is, decoders that are computed once at the beginning of the experiment and that remain unchanged throughout the BCI use. However, this approach might be inadequate in effectively handling the non-stationary nature of electroencephalography (EEG) signals and the learning that accompanies BCI use as parameters are expected to change, all the more in a real-time setting. To address this limitation, we have developed an adaptive classifier that updates its parameters based on the incoming data in real time. We first identified optimal parameters (the update coefficient, UC) to be used in an adaptive Linear Discriminant Analysis (LDA) classifier, using a previously recorded EEG dataset, acquired while healthy participants controlled a binary BCI based on imagined syllable decoding. We subsequently tested the effectiveness of this optimization in a real-time BCI-control setting. Twenty healthy participants performed two BCI-control sessions based on the imagery of two syllables, using a static LDA and the other the adaptive LDA classifier, in randomized order. In this real-time BCI-control task, the adaptive classifier led to better performances than the static one. Furthermore, the optimal parameters for the adaptive classifier were closely aligned in both datasets acquired with the same syllable imagery task. These findings highlight the effectiveness and re-liability of adaptive LDA classifiers for real-time imagined speech decoding, and its interest for non-invasive EEG-based BCI notably characterized by low decoding accuracies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wu, S., Bhadra, K., Giraud, A.-L., Marchesotti, S.. 2023-12-13. Adaptive LDA classifier enhances real-time control of an EEG Brain-computer interface for imagined-speech decoding. https://doi.org/10.1101/2023.12.12.571206

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗