bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.11.02.565254

The Influence of Knee Varus Deformity on the Kinematic and Dynamic Characteristics of Musculoskeletal Models During Gait

Abstract

BackgroundMusculoskeletal modeling has paved the way of measuring kinematic and kinetic variables during motions. Nonetheless, since the commonly-used generic models are created based on averaged data; thus, they cannot accurately mimic subjects with skeletal deformities. To overcome this obstacle, one can build personalized models based on subjects MRI or CT scan data, which is both time and money consuming. The other promising way is to manipulate generic models and create semi-personalized models to match with the individuals skeletal system at the joint of interest. Research QuestionCan a semi-personalized model reduce marker error in gait analysis? How a semi-personalized model differentiates the ROM of the lower limb joints and muscle activation pattern while having varus deformity? MethodWe developed the varus-valgus tool (freely available on: https://simtk.org/projects/var-val-tool) in MATLAB using OpenSim Application Programming Interface (API) to incorporate varus-valgus deformity in the generic OpenSim models. A 36-year-old female subject with a complaint of knee pain participated in our study. The subject had 6.5 and 11.9 degrees of varus in the right and left leg, respectively. A semi-personalized model of the subject was first created using generic OpenSim models. Then, markers error during Inverse Kinematic (IK), joints Range of Motion (ROM) and the activation of Tensor Fasciae Latae (TFL), a knee adductor, and Gracilis, a knee abductor, were calculated and compared between a semi-personalized model and a generic model. ResultsSignificant difference was observed in markers error during IK between generic and semipersonalized models (p<0.05). Substantial alterations were found in the ROM of the hip, knee and ankle joints while using semi-personalized model. Moreover, the activation pattern of TFL experienced a dramatic rise whereas Gracilis saw a fall during each gait cycle in semi-personalized models. SignificanceImplementing varus-valgus deformity in the generic models substantially reduces markers error which leads to more accurate results. It was observed that semi-personalized models showed different ROM compared to generic ones.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tabeiy, S., Karimpour, M., Shirvani, A., Sherafat Vaziri, A.. 2023-11-04. The Influence of Knee Varus Deformity on the Kinematic and Dynamic Characteristics of Musculoskeletal Models During Gait. https://doi.org/10.1101/2023.11.02.565254

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

SpiraMed: A Stereotactic Helix-based Therapy Delivery system for the Human Brain

Stereotactic needle-based delivery remains the standard for local administration of Advanced Therapy Medicinal Products (ATMPs) to the human brain. ATMP administration typically involves multiple trajectories, presenting cumulative risks and prolonging surgery. Reflux-prone, patchy therapy coverage compromises clinical results. We demonstrate a novel approach, deploying a helical delivery catheter via a single access trajectory per target, referred to as SpiraMed. Helix retraction is synchronised with therapy delivery, enabling comprehensive target coverage in seconds. Helix pitch and diameter can be precisely tailored to patient-specific target volume and vascular anatomy, as part of the preoperative stereotactic surgical planning process. Testing in agarose phantoms, live sheep and cadaveric human brain confirms enhanced therapy delivery volume, delivery speed and target coverage, with reductions in reflux and predicted risk of bleeding complication. SpiraMed represents a new paradigm, promising to help deliver on the transformative potential of cell and gene therapies across the spectrum of human CNS disease.

bioengineering↗

AtomWeaver: Multi-Component Flow Matching with a Structured Geometric Prior Facilitates Non-Canonical Peptide Design

Fixed-backbone sequence discovery, or inverse folding, is a critical recurring task in the development of new polypeptide therapeutics. Once promising backbones are established for a target pocket, computational inverse folding methods greatly help accelerate generation of candidate sequences. Such methods are mature for the traditional case of limiting to the fixed twenty-letter canonical vocabulary; however, they cannot access the broader space of non-canonical amino acids (NCAAs). This design constraint is exacerbated for peptide binders, a fast-growing modality that readily incorporates NCAAs, though in practice non-canonical design frequently depends on laborious medicinal-chemistry campaigns. An extension of inverse folding to NCAAs is thus critical to accelerating design of novel therapeutic peptides. AtomWeaver uses a joint all-site, atom-level generative scheme that does not restrict side-chain categorical assignment by either predetermined or co-resolving residue identity. Conditioned only on a fixed peptide backbone and its target protein, its multi-component flow guides side-chain atoms as unlabeled points in R3 from a nested shell prior to a variable-count final atom cloud. Identity is then read by matching each predicted cloud against a reference library of canonical and non-canonical templates. Since identity is decided only at decode time, the addressable vocabulary is a property of the library rather than of the trained weights: a new NCAA costs one reference structure and no retraining, and the model can select residues it was never prompted for and never saw in training. On a deep mutational scan of two peptide-target systems, AtomWeaver's canonical readout shows high observed mean agreement with experimental values among the compared inverse-folding methods. In the mixed canonical-noncanonical setting that canonical-only baselines cannot support at all, it likewise retains ranking signal across both systems. AtomWeaver also displayed self-consistent designs on de novo binder backbones, with the highest interface confidence among compared methods. Notably, it reached these metrics while achieving broad empirical coverage of our 300-residue vocabulary, including four non-canonical types never visible in training. AtomWeaver thus serves canonical and non-canonical peptide design alike, while transforming residue vocabulary to an expandable inference-time choice.

bioengineering↗

The Influence of Obesity and Body Shape on Sagittal Plane Knee Kinematics and Kinetics during Obstacle Crossing

Altered walking mechanics in individuals with obesity can contribute to knee osteoarthritis. The gait deviations may become more pronounced during obstacle crossing. In women, body fat distribution may further influence knee load, especially when excess fat accumulates in the thighs and hips. However, relatively little is known about how regional fat distribution affects gait in women with obesity. This study investigated how obesity and, among women, different fat distributions (Apple: more abdominal fat; Pear: more lower-limb fat) influence knee biomechanics during walking with and without obstacle crossing. Participants were 15 controls without obesity (NB) and 27 with obesity (OB). Within female participants, 10 without obesity (fNB) were compared with 20 with obesity, stratified by waist-hip ratio (Apple:10, Pear:10). Speed-adjusted statistical parametric mapping applied a general linear model (NB vs. OB) and an analysis of covariance (fNB vs. Apple vs. Pear). OB exhibited a significantly greater late-stance knee extension moment than NB across all tasks, and this difference persisted among fNB, Apple, and Pear in obstacle tasks (p<0.05). OB walked with reduced knee flexion during the early-stance leading limb after crossing a medium-height obstacle (p=0.048) and a high-height obstacle (p=0.008) compared to NB. There were significant body-shape effects (p<0.05), and post-hoc comparisons confirmed that Pear had lower knee angles than fNB in both leading-limb conditions after crossing medium- and high-height obstacles (p=0.008 and p=0.001, respectively). These findings suggest that obstacle crossing helps illuminate how excess weight influences knee biomechanics, and how regional fat distribution modulates the degree of this alteration.

bioengineering↗