Closed-Loop Estimation of Neurostimulation Strength-Duration Curve Using Fisher Information Optimization and Comparison With Uniform and Random Methods

Abstract

BackgroundStrength-duration (SD) curve, rheobase and chronaxie parameters provide insights about the interdependence between stimulus strength and stimulus duration (or pulse width), and the neural activation dynamics such as the membrane time constant, which are useful for diagnostics and therapeutic applications. The existing SD curve estimation methods are based on open-loop uniform and/or random selection of the pulse widths. ObjectiveTo develop a method for closed-loop estimation of the SD curve. MethodIn the proposed method, after the selection of each pulse width through Fisher information matrix (FIM) optimization, the corresponding motor threshold (MT) is computed, the SD curve estimation is updated, and the process continues until satisfaction of a stopping rule based on the successive convergence of the SD curve parameters. The results are compared with various uniform methods where pulse widths are chosen in ascending, descending and random orders, and with methods with two and all non-uniform random pulse widths. Results160 simulation cases were run. The FIM method satisfied the stopping rule in 144 runs, and estimated the rheobase (chronaxie in parenthesis) with an average absolute relative error (ARE) of 1.73% (2.46%), with an average of 82 samples. At this point, methods with two and all random pulse widths, and uniform methods with descending, ascending and random orders led to 5.66% (20.27%), 2.15% (4.51%), 8.57% (54.96%), 3.52% (5.45%), and 2.19% (4.40%) AREs, which are greater than that achieved through the FIM method. In all 160 runs, The FIM method has chosen the minimum and maximum pulse widths as the optimal pulse widths. ConclusionsThe SD curve is identifiable by acquiring the SD data from the minimum and maximum pulse widths achieved through the FIM optimization. The SD data at random or uniform pulse widths from only the vertical area or lower plateau of the curve might not result in satisfactory estimation. SignificanceThis paper provides insights about pulse widths selection in closed-loop and open-loop SD curve estimation methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alavi, S. M. M.. 2023-10-22. Closed-Loop Estimation of Neurostimulation Strength-Duration Curve Using Fisher Information Optimization and Comparison With Uniform and Random Methods. https://doi.org/10.1101/2023.10.19.563097

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗