bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.10.10.561676

Are Electrical Characterizations Consistent with the Cytochrome Structures of Geobacter 'Nanowires'

Abstract

Electrically conductive filaments from Geobacter sulfurreducens were reported to be pili with metallic-like conductivity, and yet were later shown to be redox-active cytochromes by cryogenic electron microscopy. It has recently been argued that the filaments were simply misidentified, implying that key observations formerly used to refute the involvement of cytochromes in conductivity now must be ascribed to them. Herein, the temperature, pH, voltage, crystallinity, charge propagation, and aromatic density-related dependencies of the conductivity reported for putative pili are re-examined in light of the CryoEM structures of cytochrome filaments. It is demonstrated that: O_LIElectrons flow through cytochrome filaments in a succession of redox reactions for which the energetics are physically constrained and the kinetics are largely independent of protein identity for highly conserved heme packing geometries. Computed heme-to-heme electron transfer rates in cytochrome filaments agree, on average, within a factor of 10 of rates experimentally determined in other multi-heme proteins with the same heme packing geometries. C_LIO_LIT-stacked heme pairs, which comprise nearly or exactly half of all heme pairs in cytochrome filaments are electronic coupling-constrained bottlenecks for electron transfer that set the rate-limiting reaction to the {micro}s timescale, which is fast enough compared to typical ms enzymatic turnover. Tuning the conductivity of cytochromes over the reported [~]107-fold range for filaments from G. sulfurreducens strains with pili variants seems both physically implausible and physiologically irrelevant if those filaments are supposed to be cytochromes. C_LIO_LIThe protein-limited flux for redox conduction through a 300-nm filament of T- and slip-stacked heme pairs is predicted to be [~]0.1 pA; a G. sulfurreducens cell discharging [~]1 pA/s would need at least 10 filaments, which is consistent with experimental estimates of filament abundance. The experimental currents for the Omc- S and Z filaments at a physiologically relevant 0.1 V bias, however, are [~]10 pA and [~]10 nA, respectively. Some of the discrepancy is attributable to the experimental conditions of a dehydrated protein adsorbed on a bear Au- electrode that contacts [~]102 hemes, and in the case of conducting probe atomic force microscopy, is crushed under forces known to deform and change the electron transport mechanism through more highly-structured proteins. C_LIO_LIPreviously observed hallmarks of synthetic organic metallic-like conductivity ascribed to pili are inconsistent with the structurally resolved cytochrome filaments under physiological conditions, including (I) increased crystallinity promoting electron delocalization, (II) carbon nanotube-like charge propagation, and (III) an exponential increase-then-decrease in conductivity upon cooling, which was only explain by a model predicted on redox potentials known to be experimentally false. Furthermore, spectroscopic structural characterizations of OmcZ that attest to a huge acid-induced transition to a more crystalline state enhancing conductivity either strongly disagree with CryoEM analyses at higher pH values or give inconclusive results that can be overly interpreted. C_LI Overall, a significant discrepancy currently exists--not between theory and experiment--but between the CryoEM cytochrome filament structure in one hand and the other functional characterizations of Geobacter nanowires in the other. The CryoEM structures, theoretical models, biological experiments, and kinetic analyses are all in agreement about the nature and rate of electron transfer in multi-heme architectures under physiological conditions, and stand opposed to the solid-state functional characterizations of Geobacter filaments reported to date. The physiological relevance and/or physical plausibility of some experiments should be examined further.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Guberman-Pfeffer, M. J.. 2023-10-12. Are Electrical Characterizations Consistent with the Cytochrome Structures of Geobacter 'Nanowires'. https://doi.org/10.1101/2023.10.10.561676

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗