bioRxiv · 10.1101/2023.09.22.558790
Microfluidic interfaces for chronic bidirectional access to the brain.
Abstract
AO_SCPLOWBSTRACTC_SCPLOWHere, we used micron-scale 3D printing to develop microfluidic interfaces which provide chronic fluidic access to the brain of preclinical research models. In mice, we show the delivery interface enables faster, more precise and physiologically less disruptive fluid injection. Moreover, we demonstrate the blood brain barrier (BBB) is intact after chronic implantation of the sampling interface and establish frequent, longitudinal sampling of CSF and biomarkers from the ventricle over long time periods of up to 200 days.
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Marcigaglia, S., De Plus, R., Vandendriessche, C., Cuypers, M.-L., Cools, J., Hoffman, L., Vandenbroucke, R., Dewilde, M., Haesler, S.. 2023-09-22. Microfluidic interfaces for chronic bidirectional access to the brain.. https://doi.org/10.1101/2023.09.22.558790
Cite the original work for its findings. Save a collection to share your selection of sources.