bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.09.04.556283

Reliability of the TMS-evoked potential in dorsolateral prefrontal cortex

Abstract

BackgroundWe currently lack a robust and reliable method to probe cortical excitability noninvasively from the human dorsolateral prefrontal cortex (dlPFC), a region heavily implicated in psychiatric disorders. We recently found that the strength of early and local dlPFC single pulse transcranial magnetic stimulation (TMS)-evoked potentials (EL-TEPs) varied widely depending on the anatomical subregion probed, with more medial regions eliciting stronger responses than anterolateral sites. Despite these differences in amplitude of response, the reliability at each target is not known. ObjectiveTo evaluate the reliability of EL-TEPs across the dlPFC. MethodsIn 15 healthy subjects, we quantified within-session reliability of dlPFC EL-TEPs after single pulse TMS to six dlPFC subregions. We evaluated the concordance correlation coefficient (CCC) across targets and analytical parameters including time window, quantification method, region of interest, sensor-vs. source-space, and number of trials. ResultsAt least one target in the anterior and posterior dlPFC produced reliable EL-TEPs (CCC>0.7). The medial target was most reliable (CCC = 0.78) and the most anterior target was least reliable (CCC = 0.24). ROI size and type (sensor vs. source space) did not affect reliability. Longer (20-60 ms, CCC = 0.62) and later (30-60 ms, CCC = 0.61) time windows resulted in higher reliability compared to earlier and shorter (20-40 ms, CCC 0.43; 20-50 ms, CCC = 0.55) time windows. Peak-to-peak quantification resulted in higher reliability than the mean of the absolute amplitude. Reliable EL-TEPs (CCC up to 0.86) were observed using only 25 TMS trials for a medial dlPFC target. ConclusionsMedial TMS location, wider time window (20-60ms), and peak-to-peak quantification improved reliability. Highly reliable EL-TEPs can be extracted from dlPFC after only a small number of trials. HighlightsO_LIMedial dlPFC target improved EL-TEP reliability compared to anterior targets. C_LIO_LIAfter optimizing analytical parameters, at least one anterior and one posterior target was reliable (CCC>0.7). C_LIO_LILonger (20-60 ms) and later (30-60 ms) time windows were more reliable than earlier and shorter (20-40 ms or 20-50 ms) latencies. C_LIO_LIPeak-to-peak quantification resulted in higher reliability compared to the mean of the absolute amplitude. C_LIO_LIAs low as 25 trials can yield reliable EL-TEPs from the dlPFC. C_LI

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gogulski, J. D., Cline, C. C., Ross, J. M., Parmigiani, S., Keller, C. J.. 2023-09-05. Reliability of the TMS-evoked potential in dorsolateral prefrontal cortex. https://doi.org/10.1101/2023.09.04.556283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗