bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.07.10.548397

Spontaneous Alignment of Myotubes through Myogenic Progenitor Cell Migration

Abstract

In large volume muscle injuries, widespread damage to muscle fibers and the surrounding connective tissue prevents myogenic progenitor cells (MPCs) from initiating repair. There is a clinical need to rapidly fabricate large muscle tissue constructs for integration at the site of large volume muscle injuries. Most strategies for myotube alignment require microfabricated structures or prolonged orientation times. We utilize the MPCs natural propensity to close gaps across an injury site to guide alignment on collagen I. When MPCs are exposed to an open boundary free of cells, they migrate unidirectionally into the cell-free region and align perpendicular to the original boundary direction. We study the utility of this phenomenon with biotin - streptavidin adhesion to position the cells on the substrate, and then demonstrate the robustness of this strategy with unmodified cells, creating a promising tool for MPC patterning without interrupting their natural function. We pre-position MPCs in straight-line patterns separated with small gaps. This temporary positioning initiates the migratory nature of the MPCs to align and form myotubes across the gaps, similar to how they migrate and align with a single open boundary. There is a directional component to the MPC migration perpendicular (90{degrees}) to the original biotin-streptavidin surface patterns. The expression of myosin heavy chain, the motor protein of muscle thick filaments, is confirmed through immunocytochemistry (ICC) in myotubes generated from MPCs in our patterning process, acting as a marker of skeletal muscle differentiation. The rapid and highly specific binding of biotin-streptavidin allows for quick formation of temporary patterns, with MPC alignment based on natural regenerative behavior rather than complex fabrication techniques. Impact StatementPositioning myogenic progenitor cells (MPCs) into straight-line patterns with intentional spacings initiates the migration of these cells to bridge these gaps, mimicking their behavior in response to small-scale injuries. By creating repetitions of patterned cells and spacings, we have demonstrated rapid migration and alignment of MPCs, which differentiate into a long-range 2D layer of aligned myotubes.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mehanna, L. E., Osborne, A. R., Peterson, C. A., Berron, B. J.. 2023-07-11. Spontaneous Alignment of Myotubes through Myogenic Progenitor Cell Migration. https://doi.org/10.1101/2023.07.10.548397

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗