bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.07.10.548389

3D bioprinting directly affects proteomic signature and myogenic maturation in muscle pericytes-derived human myo-substitute.

Abstract

Skeletal muscle tissue engineering (SMTE) has recently emerged to address major clinical challenges such as volumetric muscle loss. Here, we report a rotary wet-spinning (RoWS) biofabrication technique for producing human myo-substitutes with biomimetic architectures and functions. We show how the proposed technique may be used to establish a well-tailored, anisotropic microenvironment that promotes exceptional myogenic differentiation of human skeletal muscle-derived pericytes (hPeri). Using high-resolution mass spectrometry-based proteomics with the integration of literature-derived signaling networks, we uncovered that i) 3D biomimetic matrix environment (PEG-Fibrinogen) confers a lower mitogenicity microenvironment compared to standard 2D cultures, favoring the formation of contractile-competent bundles of pericytes-derived myotubes in an anchoring-independent 3D state, and ii) the bioprinting method promotes an upregulation of muscle matrix structural protein besides increasing contractile machinery proteins with respect to 3D bulk cultures. Finally, in vivo investigations demonstrate that the 3D bioprinted myo-substitute is fully compatible with the host ablated muscular tissue, exhibiting myo-substitute engraftment and muscle regeneration in a mouse VML model. Overall, the results show that 3D bioprinting has a superior capability for controlling the myogenic differentiation process on a macroscale and, with future refining, may have the potential to be translated into clinical practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Reggio, A., Fuoco, C., De Paolis, F., Testa, S., Celikkin, N., Bernardini, S., Baldi, J., Biagini, R., Seliktar, D., Cirillo, C., Grumati, P., Cannata, S., Costantini, M., Gargioli, C.. 2023-07-11. 3D bioprinting directly affects proteomic signature and myogenic maturation in muscle pericytes-derived human myo-substitute.. https://doi.org/10.1101/2023.07.10.548389

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗