bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.05.28.542658

An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model

Abstract

The objective of this study was to determine compressive loads that could be generated using a tibial plateau leveling osteotomy (TPLO) jig with a tensioned strand of 18-gauge stainless steel orthopedic wire in a simulated transverse fracture model. The wire was sequentially tensioned using heavy needle holders or an AO wire tightener. Recorded loads were subsequently compared to loads generated by applying a 3.5 mm limited contact-dynamic compression plate (LC-DCP) as a compression plate. Two segments of 2 cm diameter Delrin rod were placed in a testing apparatus and used to simulate a transverse fracture. A load cell was interposed between the two segments to measure the compressive loads generated during the application of the TPLO jig or the LC-DCP. Compression was generated by sequential tensioning a strand of 18-gauge wire secured through the base of the arms of the TPLO jig or by placing one or two load screws in the LC-DCP. Wires were tensioned using heavy needle holders or an AO wire tightener. Eight replicates of each construct were tested. Recorded loads were compared using a one-way repeated measures ANOVA and Tukey Honestly Significant Difference test. The wire being tensioned broke while attempting a second quarter rotation of the needle holders and when the crank handle of the AO wire tightener was advanced beyond two rotations. The mean + SD peak compressive loads recorded when tensioning the wire using the heavy needle holders and AO wire tightener was 148 {+/-} 7 N and 217 {+/-} 16 N, respectfully. The mean {+/-} SD load recorded after placement of the first and second load screw in the LC-DCP was 131 {+/-} 39 N and 296 {+/-} 49 N, respectively. The compression generated by placing two load screws in the LC-DCP was superior to the compression generated using the jig. The maximum load recorded by tensioning the wire secured through the TPLO jig using the AO wire tightener was superior to the compression generated by placing a single load screw and tensioning the wire using needle holders. Our results demonstrate that the TPLO jig allows surgeons to compress transverse fractures or osteotomies effectively. Tensioning the AO wire tightener allows for sequential tensioning and generates superior compressive loads than tensioning wires with heavy needle holders.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

ferrigno, c. r. a., Diggs, G., Lewis, D. D., Banks, S.. 2023-05-30. An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model. https://doi.org/10.1101/2023.05.28.542658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗