bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.04.30.535834

Multimodal engineering of extracellular vesicles for efficient intracellular protein delivery

Abstract

Extracellular vesicles (EVs) are promising tools to transfer macromolecular therapeutic molecules to recipient cells, however, efficient functional intracellular protein delivery by EVs remains challenging. Here, we have developed novel and versatile systems that leverage selected molecular tools to engineer EVs for robust cytosolic protein delivery both in vitro and in vivo. These systems, termed VSV-G plus EV-sorting Domain-Intein-Cargo (VEDIC) and VSV-G-Foldon-Intein-Cargo (VFIC), exploit an engineered mini-intein (intein) protein with self-cleavage activity to link cargo to an EV-sorting domain and release it from the EV membrane inside the EV lumen. In addition, we utilize the fusogenic protein VSV-G to facilitate endosomal escape and cargo release from the endosomal system to the cytosol of recipient cells. Importantly, we demonstrate that the combination of the self-cleavage intein, fusogenic protein and EV-sorting domain are indispensable for efficient functional intracellular delivery of cargo proteins by engineered EVs. As such, nearly 100% recombination and close to 80% genome editing efficiency in reporter cells were observed by EV-transferred Cre recombinase and Cas9/sgRNA RNPs, respectively. Moreover, EV-mediated Cre delivery by VEDIC or VFIC engineered EVs resulted in significant in vivo recombination in Cre-LoxP R26-LSL-tdTomato reporter mice following both local and systemic injections. Finally, we applied these systems for improved treatment of LPS-induced systemic inflammation by delivering a super-repressor of NF-B activity. Altogether, this study describes a platform by which EVs can be utilized as a vehicle for the efficient intracellular delivery of macromolecular therapeutics for treatments of disease. Graphic summary: Development of VEDIC and VFIC systems for high-efficiency intracellular protein delivery in vitro and in vivo.Intein in tripartite fusion protein (EV-sorting Domain-Intein-Cargo) performs C-terminal cleavage during the process of EV-biogenesis, resulting in enriched free cargo proteins inside of vesicles. Together with fusogenic protein, VSV-G, these engineered EVs achieve high-efficiency intracellular delivery of cargo protein (Cre and super repressor of NF-B) or protein complex (Cas9/sgRNA RNPs) both in reporter cells and in mice models. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=142 SRC="FIGDIR/small/535834v4_ufig1.gif" ALT="Figure 1"> View larger version (41K): org.highwire.dtl.DTLVardef@d0da37org.highwire.dtl.DTLVardef@1a6514corg.highwire.dtl.DTLVardef@235c9aorg.highwire.dtl.DTLVardef@194bbfa_HPS_FORMAT_FIGEXP M_FIG C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Liang, X., Gupta, D., Xie, J., Wonterghem, E. V., Hoecke, L. V., Hean, J., Niu, Z., Wiklander, O. P. B., Zheng, W., Wiklander, R. J., He, R., Mamand, D. R., Bost, J., Zhou, G., Zhou, H., Roudi, S., Zickler, A. M., Gorgens, A., Hagey, D., de Jong, O. G., Uy, A. G., Zong, Y., Mager, I., Perez, C. M., Roberts, T. C., Vader, P., Vandenbroucke, R. E., Nordin, J. Z., EL Andaloussi, S.. 2023-05-01. Multimodal engineering of extracellular vesicles for efficient intracellular protein delivery. https://doi.org/10.1101/2023.04.30.535834

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗