bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.01.31.526532

Extracellular Vesicles from Inflammation-Primed Adipose-Derived Stem Cells Enhance Achilles Tendon Repair by Reducing Inflammation and Promoting Intrinsic Healing

Abstract

Achilles tendon rupture is a common sports-related tendon injury. Even with advanced clinical treatments, many patients suffer from long-term pain and reduced function. These unsatisfactory outcomes result primarily from an imbalanced injury response with excessive inflammation and inadequate regeneration. Prior studies showed that extracellular vesicles from inflammation-primed adipose-derived stem cells (iEVs) can attenuate inflammation in the early phase of tendon healing. However, the effect of iEVs on tendon inflammation and regeneration in the later phases of tendon healing and the underlying mechanism remain to be determined. Accordingly, this study investigated the mechanistic roles of iEVs in regulating tendon response to injury using a mouse Achilles tendon injury and repair model in vivo and iEV-macrophage and iEV-tendon cell co-culture models in vitro. Results showed that iEVs promoted tendon anti-inflammatory gene expression and reduced mononuclear cell infiltration in the remodeling phase of tendon healing. iEVs also increased injury site collagen deposition and promoted tendon structural recovery. As such, mice treated with iEVs showed less peritendinous scar formation, much lower incidence of postoperative tendon gap or rupture, and faster functional recovery compared to untreated mice. Further in vitro study revealed that iEVs both inhibited macrophage inflammatory response and increased tendon cell proliferation and collagen production. The iEV effects were partially mediated by miR-147-3p, which blocks the toll-like receptor 4/NF-{kappa}B signaling pathway that activates macrophage M1 polarization. The combined results demonstrated that iEVs are a promising therapeutic agent, which can enhance tendon repair by attenuating inflammation and promoting intrinsic healing. Significance statementUsing a clinically relevant mouse Achilles tendon injury and repair model, this study revealed that iEVs, a biological product generated from inflammation-primed adipose-derived stem cells, can directly target both macrophages and tendon cells and enhance tendon structural and functional recovery by limiting inflammation and promoting intrinsic healing. Results further identified miR-147-3p as one of the active components of iEVs that modulate macrophage inflammatory response by inhibiting toll-like receptor 4/NF-{kappa}B signaling pathway. These promising findings paved the road toward clinical application of iEVs in the treatment of tendon injury and other related disorders.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shen, H., Lane, R. A.. 2023-02-03. Extracellular Vesicles from Inflammation-Primed Adipose-Derived Stem Cells Enhance Achilles Tendon Repair by Reducing Inflammation and Promoting Intrinsic Healing. https://doi.org/10.1101/2023.01.31.526532

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗