bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.01.10.523472

Firing-rate-modulated spike detection and neural decoding co-design

Abstract

ObjectiveTranslational efforts on spike-signal-based implantable brain-machine interfaces (BMIs) are increasingly aiming to minimise bandwidth while maintaining decoding performance. Developing these BMIs requires advances in neuroscience and electronic technology, as well as using low-complexity spike detection algorithms and high-performance machine learning models. While some state-of-the-art BMI systems jointly design spike detection algorithms and machine learning models, it remains unclear how the detection performance affects decoding. ApproachWe propose the co-design of the neural decoder with an ultra-low complexity spike detection algorithm. The detection algorithm is designed to attain a target firing rate, which the decoder uses to modulate the input features preserving statistical invariance. Main resultsWe demonstrate a multiplication-free fixed-point spike detection algorithm with nearly perfect detection accuracy and the lowest complexity among studies we have seen. By co-designing the system to incorporate statistically invariant features, we observe significantly improved long-term stability, with decoding accuracy degrading by less than 10% after 80 days of operation. Our analysis also reveals a nonlinear relationship between spike detection and decoding performance. Increasing the detection sensitivity improves decoding accuracy and long-term stability, which means the activity of more neurons is beneficial despite the detection of more noise. Reducing the spike detection sensitivity still provides acceptable decoding accuracy whilst reducing the bandwidth by at least 30%. SignificanceOur findings regarding the relationship between spike detection and decoding performance can provide guidance on setting the threshold for spike detection rather than relying on training or trial-and-error. The trade-off between data bandwidth and decoding performance can be effectively managed using appropriate spike detection settings. We demonstrate improved decoding performance by maintaining statistical invariance of input features. We believe this approach can motivate further research focused on improving decoding performance through the manipulation of data itself (based on a hypothesis) rather than using more complex decoding models.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhang, Z., Constandinou, T.. 2023-01-11. Firing-rate-modulated spike detection and neural decoding co-design. https://doi.org/10.1101/2023.01.10.523472

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗