bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.10.26.513872

Concurrent Contribution of Co-contraction to Error Reduction during Dynamic Adaptation of the Wrist

Abstract

MRI-compatible robots provide a means of studying brain function involved in complex sensorimotor learning processes, such as adaptation. To properly interpret the neural correlates of behavior measured using MRI-compatible robots, it is critical to validate the measurements of motor performance obtained via such devices. Previously, we characterized adaptation of the wrist in response to a force field applied via an MRI-compatible robot, the MR-SoftWrist. Compared to arm reaching tasks, we observed lower end magnitude of adaptation, and reductions in trajectory errors beyond those explained by adaptation. Thus, we formed two hypotheses: that the observed differences were due to measurement errors of the MR-SoftWrist; or that impedance control plays a significant role in control of wrist movements during dynamic perturbations. To test both hypotheses, we performed a two-session counterbalanced study. In both sessions, participants performed wrist pointing in three force field conditions (zero force, constant, random). Participants used either the MR-SoftWrist or the UDiffWrist, a non-MRI-compatible wrist robot, for task execution in session one, and the other device in session two. To measure anticipatory co-contraction associated with impedance control, we collected surface EMG of four forearm muscles. We found no significant effect of device on behavior, validating the measurements of adaptation obtained with the MR-SoftWrist. EMG measures of co-contraction explained a significant portion of the variance in excess error reduction not attributable to adaptation. These results support the hypothesis that for the wrist, impedance control significantly contributes to reductions in trajectory errors in excess of those explained by adaptation.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Farrens, A. J., Schmidt, K., Cohen, H., Sergi, F.. 2022-10-27. Concurrent Contribution of Co-contraction to Error Reduction during Dynamic Adaptation of the Wrist. https://doi.org/10.1101/2022.10.26.513872

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗