Analyses of single extracellular vesicles from non-small lung cancer cells to reveal effects by Epidermal growth factor inhibitor treatments

Abstract

Precision cancer medicine have changed the treatment landscape of non-small cell lung cancer (NSCLC) as illustrated by tyrosine kinase inhibitors (TKIs) towards mutated Epidermal growth factor receptor (EGFR). Yet, responses to such TKIs e.g., erlotinib and osimertinib among patients are heterogenous and there is a need for non-invasive blood-based analytics to follow treatment response and reveal resistance to improve patients treatment outcome. Recently, extracellular vesicles (EVs) have been identified as an important source of tumor biomarkers promising to revolutionize liquid biopsy-based diagnosis of cancer. However, high heterogeneity has been a major bottleneck. The pathological signature is often hidden in the differential expression of membrane proteins in a subset of EVs which are difficult to identify with bulk techniques. Using a fluorescence-based approach, we for the first time demonstrate that the single-EV technique can be used to monitor the treatment response of targeted cancer therapies such as TKIs towards EGFR. To test the hypothesis, we analyzed the membrane proteins of native EVs extracted from EGFR-mutant NSCLC cell line, both prior and post treatment with EGFR-TKIs erlotinib or osimertinib. The selected cell line being refractory to erlotinib and responsive to osimertinib makes it a suitable model system. The expression level of five surface proteins; two common tetraspanins (CD9, CD81) and three markers of specific interest in lung cancer (EGFR, PD-L1, HER2) were studied. The data suggest that in contrast to erlotinib, the osimertinib treatment increases the population of PD-L1, EGFR and HER2 positive EVs while the expression level per EV decreases for all the three markers. The PD-L1 and HER2 expressing EV population seems to increase by several fold because of osimertinib treatment. The observations agree with the previous reports performed on cellular level indicating the biomarker potential of EVs for liquid-biopsy based monitoring of targeted cancer treatments. HighlightsO_LIMembrane protein analyses of single EVs may reveal distinct differences when lung cancer cells are refractory vs responsive under different EGFR-TKI treatments. C_LIO_LIComparison of 1st generation erlotinib and 3rd generation osimertinib shows clear signature on the expression of PD-L1, EGFR, HER2 on single EVs C_LIO_LIColocalization showed a change in common marker combinations before after treatment. C_LIO_LIPD-L1 expression per vesicle decreases while the number of PD-L1 positive EVs increases as a result of osimertinib treatment, indicating that such signature may not be detectable under bulk analysis C_LI

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stridfeldt, F., Cavallaro, S., Haag, P., Lewensohn, R., Linnros, J., Viktorsson, K., Dev, A.. 2022-10-18. Analyses of single extracellular vesicles from non-small lung cancer cells to reveal effects by Epidermal growth factor inhibitor treatments. https://doi.org/10.1101/2022.10.14.512252

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗