bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.10.04.510886

The Development and Validation of a Portable, Benchtop, Hydrostatic Model to Acquire and Analyze Quantitative Data on Unused and Failed Hydrocephalus Catheters

Abstract

IntroductionDespite the prevalence of shunt failure in the treatment of hydrocephalus and the near-constant need for shunt revisions, there are a limited number of methods that yield quick, quantifiable measures of catheter obstruction. We developed and assessed a gravity-driven device that measures flow through ventricular catheters. The model provides neurosurgeons with a quick, simple device that can send useful data to researchers. It can also be used by researchers to quantitatively compare catheter obstruction between different models of catheters. The model was used in this study to quantitatively analyze unused ventricular catheters used in the treatment of hydrocephalus; failed hydrocephalus catheters from our catheter biorepository were also quantitatively analyzed using the same device. The mechanisms of catheter obstruction are still poorly understood, but the literature suggests that resistance to fluid flow plays a significant role. MethodsCatheters of three manufacturing companies were inserted into the benchtop model, which records time, flow rate, and pressure data using sensors. The relative resistances of catheters across six design models were evaluated. Experiments were performed to evaluate changes in the relative resistance of a catheter when the catheters holes were progressively closed. Relative resistance of explanted catheters from our catheter biorepository was also measured. ResultsExperimental results showed significant differences (P < 0.05) between the relative resistances of different catheter models just after being removed from their packaging. Furthermore, a trend of increasing resistance was observed in the experiments on catheters with manually plugged ventricular catheter holes. Data from five individual benchtop models were compared, and the differences in measured data between the models were found to be negligible. A significant increase (P < 0.05) in relative resistance was observed in explanted catheters. ConclusionThe current study is meant both to validate the proposed model and to examine data on differences in relative resistance among catheter models. From these experiments, we can rapidly correlate clinical patient cohorts to identify mechanisms of luminal shunt obstruction. Collecting data for predictive analyses of potential patient outcomes is an area of potential future work, assuming sufficient sample size.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gopalakrishnan, P., Faryami, A., Harris, C.. 2022-10-07. The Development and Validation of a Portable, Benchtop, Hydrostatic Model to Acquire and Analyze Quantitative Data on Unused and Failed Hydrocephalus Catheters. https://doi.org/10.1101/2022.10.04.510886

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗