bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.09.26.509461

The elasto-plastic nano- and microscale compressive behaviour of rehydrated mineralised collagen fibres

Abstract

The multiscale architectural design of bio-based nanostructured materials such as bone enables them to combine unique structure-mechanical properties that surpass classical engineering materials. In biological tissues, water as one of the main components plays an important role in the mechanical interplay, but its influence has not been quantified at the length scale of a mineralised collagen fibre. Here, we combine in situ experiments and a statistical constitutive model to identify the elasto-plastic micro- and nanomechanical fibre behaviour under rehydrated conditions. Micropillar compression and simultaneous synchrotron small angle X-ray scattering (SAXS) and X-ray diffraction (XRD) were used to quantify the interplay between fibre, mineralised collagen fibrils and mineral nanocrystals. Rehydration led to a 65% to 75% decrease of fibre yield stress and compressive strength, and a 70% decrease of stiffness with a 3x higher effect on stress than strain values. While in good agreement with bone extracellular matrix, the decrease is 1.5-3x higher compared to micro-indentation and macro-compression. Hydration has a higher influence on mineral than fibril strain while the highest difference to the macroscale was observed comparing mineral and tissue levels. Results suggest that the effect of hydration is strongly mediated by ultrastructural interfaces while corroborating the previously reported water-mediated structuring of bone apatite providing insights towards the mechanical consequences. Results show that the missing reinforcing capacity of surrounding tissue is more pronounced in wet than dry conditions when testing an excised array of fibrils, mainly related to the swelling of fibrils in the matrix. Differences leading to higher compressive strength between mineralised tissues do not seem to depend on the rehydration state while fibril mobilisation follows a similar regime in wet and dry conditions. The lack of kink bands point towards the role of water as an elastic embedding, thus, adapting the way energy is absorbed. Statement of significanceCharacterising structure-property-function relationships of biomaterials helps us to elucidate the underlying mechanisms that enables the unique properties of these architectured materials. Experimental and computational methods can advance our understanding towards their complex behaviour providing invaluable insights towards bio-inspired material development. In our study, we present a novel method for biomaterials characterisation. We close a gap of knowledge at the micro- and nanometre length scale by combining synchrotron experiments and a statistical model to describe the behaviour of a rehydrated single mineralised collagen fibre. Results suggest a high influence of hydration on structural interfaces, and the role of water as an elastic embedding. Using a statistical model, we are able to deduce the differences in wet and dry elasto-plastic properties of fibrils and fibres close to their natural hydration state.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Groetsch, A., Gourrier, A., Casari, D., Schwiedrzik, J., Shephard, J. D., Michler, J., Zysset, P. K., Wolfram, U.. 2022-09-27. The elasto-plastic nano- and microscale compressive behaviour of rehydrated mineralised collagen fibres. https://doi.org/10.1101/2022.09.26.509461

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗