bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.08.31.506042

A Camera-Assisted Pathology Microscope to Capture the Lost Data in Clinical Glass Slide Diagnosis

Abstract

Digital pathology, or the practice of acquiring, managing, and interpreting high-resolution digital images from glass pathology slides, holds much promise in precision medicine, potentially transforming diagnosis and prognosis based on computational image biomarkers derived from digital tissue images. However, for all its promise, digital imaging in pathology has not yet become an integral part of the clinical workflow as it has in radiology due to high cost, workflow disruptions, burdensome data sizes and IT requirements, and additional dedicated personnel requirements. Consequently, pathology retains the 150-year-old analog workflow, and the vast majority of slides used in clinical diagnosis are never digitized. Furthermore, there is a missed opportunity to capture the image information and associated data on search processes that led to the clinical diagnosis, which could serve as the foundation for computational clinical decision support. This paper describes an approach for slide digitization during clinical review using a camera attached to a standard brightfield pathology microscope. While a pathologist reviews a glass slide using the eyepiece oculars, the continuously running camera digitizes a complete record of the slide review, resulting in multi-resolution slide images and spatiotemporal saliency maps of the slide review. Unlike other approaches, the pathologist does not stop to review the video stream or monitor the acquisition of video frames but performs the diagnostic review at the microscope using the standard clinical protocol. This hybrid analog-digital approach combines the benefits of digital slide analysis, including annotation, computation, and the ability to confirm the completeness and quality of the glass slide review with the ease of using the microscope for primary diagnosis. Furthermore, a record of the pathologists attention during the review, including their search path, magnification level, and dwell times at each location on the slide, is obtained. In the future, this approach could enable the development and application of new and emerging computational decision-support algorithms in real-time to provide feedback to the pathologist, reduce diagnostic errors, and improve disease diagnosis and prognosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ashman, K., Cooper, M. S., Zhuge, H., Fox, S. E., Epstein, J. I., Wenk, C., Summa, B., Brown, J. Q.. 2022-09-03. A Camera-Assisted Pathology Microscope to Capture the Lost Data in Clinical Glass Slide Diagnosis. https://doi.org/10.1101/2022.08.31.506042

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗