bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.08.29.505738

Fetal QRS Detection by Multiple Channel Temporal Pattern Search Applied to the NInFEA Database

Abstract

BackgroundIn some cases, the fetal electrocardiogram (ECG) has a relatively low signal to noise ratio. Much of the literature pertaining to fetal ECG processing focuses on methods for separating the fetal ECG from the maternal ECG rather than detecting the fetal QRS in high noise conditions. This paper describes the application of a previously described pattern search methodology (TEPS) for detecting the fetal QRS in noisy ECGs. Algorithm SummarySignals are processed in non-overlapping 5 s segments. The maternal QRS peaks are detected in a segment from a reliable lead. Next, for each of a potentially large number of leads, after removing the maternal QRS peaks from the set of searchable peaks, single channel TEPS is applied to search for provisional fetal peak sequences. The provisional sequences are scored according to previously described single channel TEPS quality measures: temporal regularity, peak pair amplitude ratios, and number of skips. The provisional sequences across all leads are aggregated according to their average RR intervals and scores. The most likely average RR interval for the segment is estimated from this aggregation by forming a score weighted average of the RR intervals. Sequences with RR intervals close to the chosen RR interval are selected to form a set of high quality sequences. To account for the possibility of peak time offsets between different channels, these sequences are time aligned by time lagged cross correlation. An optimal sequence is formed from these time aligned sequences, with optimality criteria based on peak timing coherence, temporal regularity, and skips. DataThe above procedure was applied to 60 ECG signals (avg. duration approximately 31 s) from the Non-Invasive Multimodal Foetal ECG-Doppler Dataset for Antenatal Cardiology Research ("NInFEA"). The NInFEA dataset also includes ultrasound recordings from which RR intervals may be extracted. ResultsOut of 59 records, RR intervals were well tracked in 57 records. (One of the 60 NInFEA records was excluded due to the inability to obtain a sinus rhythm peak sequence from the ultrasound recording). For these 57 records, 84% and 95% of the ECG RR intervals were within 5 ms and 10 ms, respectively, of the ultrasound derived RR intervals. The mean and median average absolute value RR interval difference (between ECG and ultrasound) over 5 second segments were 3.2 ms and 2.4 ms respectively, with 93% of segments having a mean average absolute value RR interval difference less than 7ms. ConclusionThe TEPS methodology shows promise for ECG based fetal sinus rhythm monitoring.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hopenfeld, B. R.. 2022-09-01. Fetal QRS Detection by Multiple Channel Temporal Pattern Search Applied to the NInFEA Database. https://doi.org/10.1101/2022.08.29.505738

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗