bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.08.04.502722

Geometric variation of the human tibia-fibula: A public dataset of tibia-fibula surface meshes and statistical shape model

Abstract

BackgroundVariation in tibia geometry is a risk factor for tibial stress fractures. Geometric variability in bones is often quantified using statistical shape modelling. Statistical shape models (SSM) offer a method to assess three-dimensional variation of structures and identify the source of variation. Although SSM have been used widely to assess long bones, there is limited open-source datasets of this kind. Overall, the creation of SSM can be an expensive process, that requires advanced skills. A publicly available tibia shape model would be beneficial as it enables researchers to improve skills. An opensource SSM could benefit health, sport and medicine with the potential to assess geometries suitable for medical equipment, and aid in clinical diagnosis. This study aimed to: (i) quantify tibial geometry using a SSM; and (ii) provide the SSM and associated code as an open-source dataset. MethodsLower limb computed tomography (CT) scans from the right tibia-fibula of 30 cadavers (male n = 20, female n =10) were obtained from the New Mexico Decedent Image Database. Tibias were segmented and reconstructed from the CT scans into both cortical and trabecular sections. Fibulas were segmented as a singular surface. The segmented bones (cortical and trabecular tibia; and fibula) were used to develop three SSM of the: (i) tibia; (ii) combined tibia and fibula; and (iii) tibial trabecular. Principal component analysis (PCA) was applied to obtain the three SSM, with the principal components (PCs) that explained 95% of the geometric variation retained. ResultsOverall size variation was the main source of variation of all three models accounting for 90.31%, 84.24% and 85.06%, respectively. Other sources of geometric variation in the tibia surface models included overall (PC3) and midshaft thickness (PC2); prominence and size of the condyle plateau, tibial tuberosity, and anterior crest (PC4); and axial torsion of the tibial shaft (PC5). Further variations in the tibia-fibula model included midshaft thickness of the fibula (PC2); fibula head position relative to the tibia (PC2); tibia and fibula anterior-posterior curvature (PC4); fibula posterior curvature (PC5); tibia plateau rotation (PC5); and interosseous width (PC6). The main sources of variation in the tibia-trabecular model other than general size included variation in the medulla cavity diameter (PC2); overall thickness (PC3); and the relative volume of proximal and distal ends compared to middle (PC4). ConclusionImportant variations that could increase the risk of tibial stress injury were observed in the tibia and tibia-fibula SSM. These included general tibial thickness, midshaft thickness, tibial length and medulla cavity diameter (indicative of cortical thickness). Further research is warranted to better understand the effect of these tibial and fibula shape characteristics on tibial stress, loading and injury risk. This SSM and associated code has been provided in an open-source dataset. The associated code includes three example applications: (i) generation of a random sample; (ii) reconstruction of trabecular surfaces; and (iii) reconstruction from palpable landmarks. The developed tibial surface models and statistical shape model will be made available for use at: https://simtk.org/projects/ssm_tibia.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Keast, M., Bonacci, J., Fox, A.. 2022-08-05. Geometric variation of the human tibia-fibula: A public dataset of tibia-fibula surface meshes and statistical shape model. https://doi.org/10.1101/2022.08.04.502722

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗