bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.07.03.498548

3D-Printing in Radiation Oncology: Development and Validation of Custom 3D-Printed Brachytherapy Alignment Device and Phantom

Abstract

Brachytherapy seeks to treat cancer through insertion of radioactive sources aligned by needles within standardized blocking templates. However, many patients have anatomy that does not conform to standard tools. We created a 3D printed device to provide customized needle alignment for a patient. Device was validated through CT scan and treatment plan creation on a custom anatomical phantom based on patient data. CT scan of a cervix tumor from anonymized patient data was used to develop a 3D printed brachytherapy alignment tool and phantom anatomical mold. Multiple materials were evaluated to match patient anatomy in density and Hounsfield Units present on CT scan, with additional considerations for toxicity, compliance, and practicality. Alignment device and molds were developed in PLA. Silicone of T20 hardness was used to create relevant anatomical organs (Uterus, Rectum, Bladder). Tumor tissue was mimicked by addition of 1CC of Iodine contrast agent to silicone. Device and needles were arranged, inserted into anatomical phantom, and scanned by CT to mimic brachytherapy procedure. 3D printed Silicone uterus of 1.08 g/cm^3 and 40 HU mimicked human uterus on CT scan. Constructed uterus dimensions of 6.5 cm x 5.5 cm x 3.3 cm were verified on imaging to be within + 1 mm of original patient scan. The 1 CC of contrast agent provided sufficient differentiation of "tumor" ring from "tissue." CT scan and treatment plan creation verified that the alignment device provided correction insertion of needles into the phantom tumor tissue and uterus. This pilot study provides a potential methodology to develop future anatomical phantoms and alignment devices from CT scans of patient data. Additional modifications could make this a viable training tool for future residents and medical students to learn brachytherapy. Key PointsO_LI3D printing can be leveraged to create a Brachytherapy alignment device from patients anatomy. C_LIO_LIAnatomical phantom can be generated from 3D printing for use testing device or for training. C_LIO_LIRelevant materials to create phantom that mimic patients anatomy on CT scan. C_LIO_LIGeneration of a treatment plan based on CT scan was able to validate device and phantom C_LI

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Provenzano, D. J., Aghdam, H., Goyal, S., Loew, M., Rao, Y.. 2022-07-04. 3D-Printing in Radiation Oncology: Development and Validation of Custom 3D-Printed Brachytherapy Alignment Device and Phantom. https://doi.org/10.1101/2022.07.03.498548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗