bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.06.22.497125

Validation of two-dimensional video-based inference of finger kinematics with pose estimation

Abstract

Accurate capture finger of movements for biomechanical assessments has typically been achieved within laboratory environments through the use of physical markers attached to a participants hands. However, such requirements can narrow the broader adoption of movement tracking for kinematic assessment outside these laboratory settings, such as in the home. Thus, there is the need for markerless hand motion capture techniques that are easy to use and accurate enough to evaluate the complex movements of the human hand. Several recent studies have validated lower-limb kinematics obtained with a marker-free technique, OpenPose. This investigation examines the accuracy of OpenPose, when applied to images from single RGB cameras, against a gold standard marker-based optical motion capture system that is commonly used for hand kinematics estimation. Participants completed four single-handed activities with right and left hands, including hand abduction and adduction, radial walking, metacarpophalangeal (MCP) joint flexion, and thumb opposition. Accuracy of finger kinematics was assessed using the root mean square error. Mean total active flexion was compared using the Bland-Altman approach, and coefficient of determination of a linear regression. Results showed good agreement for abduction and adduction and thumb opposition activities. Lower agreement between the two methods was observed for radial walking (mean difference between the methods of 5.03{degrees}) and MCP flexion (mean difference of 6.82{degrees}) activities, due to occlusion. This investigation demonstrated that OpenPose, applied to videos captured with monocular cameras, can be used for markerless motion capture for finger tracking with an error below than 11{degrees} and on the order of that which is accepted clinically. Author summaryDecreased hand mobility may limit functionality, and its quantification is fundamental to assess underlying impairments. Optical motion capture technologies are the most accurate means by which to quantify hand motion. As this approach involves placing markers on the skin and recording hand movements using multiple cameras, there are limitations of physical space, time requirements, and financial implications. Therefore, the adoption of these practices is confined to laboratory settings. In clinical settings, goniometry is used to quantify hand range of motion (ROM), but this also involves lengthy processes and requires face-to-face assessments. Alternative solutions have been investigated to quantify hand mobility remotely and support home-based care interventions. However, none has been shown to be accurate enough to replace the gold-standard measurement of hand ROM in clinical settings. Recently, markerless technologies that leverage artificial intelligence have exhibited great potential for human movement analysis, but these studies have validated markerless tracking technologies for the lower limb only. We demonstrate that the validity of these models can be extended to capture hand mobility, making it also possible to assess hand function remotely.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gionfrida, L., Rusli, W., Bharath, A. A., Kedgley, A. E.. 2022-06-26. Validation of two-dimensional video-based inference of finger kinematics with pose estimation. https://doi.org/10.1101/2022.06.22.497125

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗