bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.05.30.493944

Topological defects govern mesenchymal condensations, offering a morphology-based tool to predict cartilage differentiation

Abstract

A critical initial stage of skeletal morphogenesis involves formation of highly compact aggregates of mesenchymal cells, known as mesenchymal condensations, appearing as regularly-spaced pattern of spots. Conventional computational models to understand their patterning have been based on chemotaxis, haptotaxis, and reaction-diffusion equations. In this work, we investigate the mesenchymal condensations from a different perspective, namely topological defects within liquid crystal-like pattern. Using bone marrow-derived mesenchymal stromal cells (bm-MSCs), we observed emergence of cellular swirls in confluent in-vitro cultures, followed by appearance of mesenchymal condensations at the centers of the selfassembled swirls. Specifically, the condensations appeared at the comet-like (+1/2) and spiral-shaped (+1) topological defect sites within the swirl pattern. Next, with the rationale that cellular swirls precede skeletal morphogenesis, and supported with the qualitative observation that swirl pattern-features are donor-specific, we probed the correlation between swirl pattern and the chondrogenic differentiation outcome of bm-MSCs. Towards this, we first generated and imaged cellular swirls systematically across 5 donors by controlling seeding density, culture vessel geometry, and culture duration. We observed that the swirl pattern features quantified as variance of coherency correlated strongly with the cartilage matrix proteins, sulfated glycosaminoglycan and collagen-II, quantified from the standard in-vitro chondrogenic differentiation assay. Our work shows that swirl-pattern quantification provides a novel and powerful tool to predict efficacy of bm-MSCs for in-vitro cartilage regeneration. Significance StatementMesenchymal condensation is a critical stage in the formation of bone and cartilage, where the mesenchymal cells form high density cell clusters that are regularly spaced. In this work, we inspect the patterning of these condensations in-vitro from a novel perspective. We first show that at high density, bone-marrow-derived mesenchymal stromal cells (bm-MSCs) self-assemble to form cellular swirls resembling the vortices in a turbulent flow. This is followed by cell aggregations at the centers of the vortices, which show correspondence to mesenchymal condensations. Interestingly, we observed that the swirl pattern made by bm-MSCs isolated from human donors, varies from individual to individual and correlates with their propensity to differentiate into cartilage. This suggests that swirl pattern quantification via image analysis can be used to predict differentiation outcome, in context of regenerative cell therapy.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Makhija, E., Zheng, Y., Wang, J., Leong, H. R., Othman, R. B., Ng, E. X., Lee, E. H., Tucker-Kellogg, L., Lee, Y. H., Yu, H., Poon, Z., Van Vliet, K. J.. 2022-05-30. Topological defects govern mesenchymal condensations, offering a morphology-based tool to predict cartilage differentiation. https://doi.org/10.1101/2022.05.30.493944

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Design of colipids with controlled lateral distance of head group moieties for targeting strategies in the field of lipid-based nanoparticles

Lipid nanoparticles and liposomes are nanoparticle drug formulations which are firmly established in clinics. In order to expand their application and improve efficacy, surface modifications can be a key strategy, especially for cell specific targeting. Targeting can be achieved by integrating ligand functionalized lipids or lipidoids on the nanoparticle surface. In this case, not solely the targeting ligand itself, but also the structure of the whole targeting lipid/lipidoid can affect the interaction of the targeting ligand with the binding motive on cells. Especially, distal spacer structures between lipid anchor and ligand unit, often composed of polyethylene glycol chains, provide a certain distance of the ligand from the nanoparticle surface. A concept which is currently neglected is the control of the lateral distance between ligand structures on the nanoparticle. Herein we investigated the possibility to design lipidoids with a lateral spacer composed of polyethylene glycol units. We synthesized and characterized different lipidoids which provide a primary amine in the head group for possible ligand coupling. In our model lipidoids the head groups were functionalized with a paramagnetic probe to apply electron paramagnetic resonance (EPR) methods for the characterization of the lipidoid interaction with model nanoparticles, in our case liposomes. Continuous wave EPR was used to study the efficiency of the novel lipidoids to integrate into lipid bilayers of model liposomes, which was shown to depend on lipidoid structure and liposome composition. Furthermore, using double electron-electron resonance (DEER), we observed lipidoid conformational changes occurring upon integration into liposomes.

biophysics↗

Beyond Sequence and Structure: Pretraining PLMs on Continuous Biophysical Fields

We introduce the Biophysical Transformer, a protein language model that adds continuous biophysical fields as a third pretraining signal beside sequence and structure. A Poisson-Boltzmann solver computes the electrostatic potential around each three-residue token, and the model learns to predict it from sequence alone. A rotationally invariant spherical-harmonic descriptor serves as the loss target, eliminating the need for frame alignment during training and for coordinates at inference. Against a matched, one-flag control on the FLIP Meltome thermostability benchmark, the field objective raises Spearman correlation on every trained head of both human splits.The gain on human survives residualizing dipeptide composition under two architecturally different readouts and survives removing the test proteins that overlap the pretraining corpus. No effect survives on the organism-mixed split. At 1.1M parameters, both the Biophysical Transformer and its sequence-only control exceed FLIP's one-hot CNN and untrained-ESM baselines on every split. All results rest on a single pretraining run per arm,and the current design does not separate field content from generic regularization.

biophysics↗

An auditable harness for biomolecular dynamics simulations by AI agents

AI agents now generate biological hypotheses faster than they can be tested. Hypotheses stated at the atomic level can be examined with molecular dynamics (MD) simulations. For new questions without a reference, trust in an agent-run simulation rests on a tool-written process record, not the agent's account. Existing MD agents leave this record to the language model. Here we present MDClaw, a harness whose validating tools and directed acyclic graph (DAG) check stages before execution and record every simulation stage. On MDDataBench, which grades outputs against deposited simulations, four open-weight models with MDClaw passed all three runs on 81-100% of 31 test systems. The DAG complements this outcome check. An ablation without the DAG revealed 11 successful runs that had skipped minimization or equilibration, or simulated a different structure. MDClaw carried questions from human and AI scientists through simulation to trajectories traceable to their inputs and settings.

biophysics↗