Lamellar Thickness Measurements in Normal and Osteogenesis Imperfecta Human Bone, with development of a method of automated thickness averaging to simplify quantitation.

Abstract

PurposeLamellar bone that forms in moderate and severe osteogenesis imperfecta (OI) is often composed of structurally irregular lamellae compared to those in normal bone. Polarization light microscopy (PLM) demonstrates lamellar bone well but has rarely been used for quantitative studies; information available on normal bone lamellae tends to be variable and studies specifically assessing OI bone lamellae have not been done. We report on PLM histomorphometry quantifying bright and dark lamellar thicknesses in normal and OI bone. Manual measurements of individual lamellar thicknesses have been made on histologic sections using the cellSens image analysis system; in an effort to augment the number of measurements we also developed a method of automated thickness averaging in quantifying regions of lamellae. MethodsFemoral and tibial cortical bone fragments from 5 individuals 5 - 26 years old (without molecular bone disorders) and 8 individuals 5 - 16 years old with progressively deforming (Sillence III) OI were obtained. The fragments were decalcified, infiltrated in JB4 solution, embedded in JB4 plastic, sectioned at 5 thickness and stained with 1% toluidine blue for light and polarizing microscopy. Manual measurements: Strict criteria for measurement, primarily to eliminate oblique lamellae, included accumulations of 16-20 bright and dark lamellae under PLM with a relatively narrow range of thicknesses, flattened elliptical osteocytes along the longitudinal axis of the lamellae and canaliculi passing from the walls of the osteocyte lacunae at right angles to the lamellae. Histomorphometric measurements of bright and dark lamellae by PLM were made at 20X magnification. Automated measurements: A script for automated measurement of average lamellar thicknesses from PLM images was developed in MATLAB (Mathworks, Natick, MA) to make measurement faster and less subjective. The script isolates a region from an image for measurement and marks each pixel as either bright or dark based on a local average intensity threshold. It then takes multiple pixel measurements along the length of the lamellae in the image and returns the average thickness of each in m. Results1. OI bone mean lamellar thickness values are always less than those in normal bone. The mean value for all OI bright and dark lamellae combined is 1.80 {+/-} 0.72 m and the value in normal bone is 2.54 {+/-} 0.92 m. 2. Mean value for the bright lamellae is less than that for the dark lamellae in both normal and OI bone. The mean value for bright lamellae in OI is 1.47 {+/-} 0.53 m and for dark lamellae 2.18 {+/-} 0.72 m; in normal bone the mean value for bright lamellae is 2.06 {+/-} 0.54 m and for dark lamellae 3.07 {+/-} 0.96 m. The differences are statistically significant: between groups of normal and OI lamellae (p<0.001), normal and OI light bands (p<0.001), and normal and OI dark bands (p<0.001). 3. Ratio of mean values for bright/dark lamellar thicknesses is the same in OI and normal bone. The ratio in OI bone is 0.67 (range: 0.54 - 0.83) and in normal bone 0.67 (range: 0.60 - 0.88). 4. Validation of automated vs. manual datasets: For each lamella in the validation dataset, the percent difference between the automated and manual measurements was calculated. The mean of the absolute values of these percent differences was 18.9%, a statistically non-significant difference (p = 0.0518). Discussion and conclusionsLamellar bone that forms in moderate and severe OI is composed of thinner and less regular lamellae than those in normal bone. i) PLM histomorphometry shows mean lamellar thicknesses (bright and dark merged) are statistically significantly decreased in OI compared to normal bone as are bright and dark lamellar thicknesses measured independently. ii) The automated method can be adapted readily to the assessment process for lamellar thicknesses and is, most likely, more accurate since it averages a greatly increased number of measurements per individual lamella. iii) Lamellar thickness measurements can be helpful in assessing the effect of specific collagen mutations on OI bone synthesis and warrant inclusion in both research and clinical histomorphometric assessments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chow, J., Ryan, N., Shefelbine, S. J., Shapiro, F.. 2022-05-31. Lamellar Thickness Measurements in Normal and Osteogenesis Imperfecta Human Bone, with development of a method of automated thickness averaging to simplify quantitation.. https://doi.org/10.1101/2022.05.30.493917

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗