bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.05.06.490211

Skull and scalp segmentation in neonatal cerebral MRI using subject-specific probability models

Abstract

This study presents a new approach for segmenting cranial bones in magnetic resonance images (MRIs) acquired from neonates in the gestational age range of 39 to 42 weeks. the approach uses subject-specific probability maps of the skull and scalp, created from atlas computed tomography (CT) images taken retrospectively from neonates in the same age range. the method also uses a subject-specific probability map of cerebrospinal fluid (CSF), constructed from retrospective atlas MRIs. To build skull, scalp, and CSF probability maps, a subject-specific bimodal MR-CT neonatal head template is employed. In the next step, the subject-specific probability maps are fed to the expectation maximization algorithm in conjunction with Markov random field method implemented in FSL software to segment the skull and scalp from the input MR image. The results of the proposed method were evaluated through various experiments. First, we employed our method as a brain tissue extractor and compared its results with public methods such as the Brain Extraction Tool (BET) and Brain Surface Extractor (BSE). Second, we calculated the similarity in shape between the frontal and occipital sutures (which had been reconstructed from segmented cranial bones) and the ground truth. For this purpose, modified versions of the Dice similarity coefficient (DSC) were adopted and used. Finally, retrospective data including MRI and CT images obtained from the same neonate within a short time interval were used. After aligning the two images, the DSC and modified Hausdorff distance (MHD) were used to compare the similarity of the cranial bones in the MR and CT images. Furthermore, the anterior fontanel size was compared to the normal size reported for neonates in the same age range. Cranial bone thickness was calculated and compared to normal values reported for healthy neonates. The results of these experiments demonstrated the success of our segmentation method. The algorithm for creating subject-specific atlases is publicly accessible through a graphical user interface at medvispy.ee.kntu.ac.ir.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hokmabadi, E., Abrishami Moghaddam, H., Mohtasebi, M., Gity, M., Wallois, F.. 2022-05-06. Skull and scalp segmentation in neonatal cerebral MRI using subject-specific probability models. https://doi.org/10.1101/2022.05.06.490211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗